Evaluation of noise equivalent count parameters as indicators of adult whole-body FDG-PET image quality
- 8 August 2013
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 27 (9) , 855-861
Abstract
Objectives The aim of this study was to assess variation of qualitative and quantitative PET/CT image quality parameters with acquisition time, injection activity and body mass for a representative group of adults undergoing whole-body PET/CT imaging. Methods PET scan data from sixty patients were reconstructed with a scan time of 1, 2 and 3 min/bed position. These images were visually scored and three quantitative parameters were calculated: noise equivalent counts per axial length (NECpatient), noise equivalent count density (NECdensity) and liver signal to noise ratio (liver SNR). The ability of the three quantitative parameters to discriminate qualitative image quality was assessed using ROC analysis. Results The quantitative parameters were shown to discriminate images of good/excellent quality from those of poorer image quality with a high degree of accuracy (ROC area >0.9); further, NECpatient had significantly higher discrimination than either NECdensity or liver SNR (ROC area = 0.97). Conclusions NECpatient, NECdensity and liver SNR all have high discrimination for qualitatively assessed PET image quality. NECpatient in particular is an effective objective indicator of patient image quality, which will help to assess and standardise scan protocols for purposes such as multi-centre research trials.Keywords
This publication has 13 references indexed in Scilit:
- Reliability of predicting image signal‐to‐noise ratio using noise equivalent count rate in PET imagingMedical Physics, 2012
- Effects of injected dose, BMI and scanner type on NECR and image noise in PET imagingPhysics in Medicine & Biology, 2011
- Standardization of Quantitative Imaging: The Time Is Right, and 18F-FDG PET/CT Is a Good Place to StartJournal of Nuclear Medicine, 2011
- Japanese guideline for the oncology FDG-PET/CT data acquisition protocol: synopsis of Version 1.0Annals of Nuclear Medicine, 2010
- Investigation of 18F-FDG 3D mode PET image quality versus acquisition timeNuclear Medicine Communications, 2010
- Improved Dose Regimen in Pediatric PETJournal of Nuclear Medicine, 2010
- FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0European Journal of Nuclear Medicine and Molecular Imaging, 2009
- Comparison of Imaging Protocols for 18F-FDG PET/CT in Overweight Patients: Optimizing Scan Duration Versus Administered DoseJournal of Nuclear Medicine, 2009
- Standards for PET Image Acquisition and Quantitative Data AnalysisJournal of Nuclear Medicine, 2009
- NEC Density and Liver ROI S/N Ratio for Image Quality Control of Whole-Body FDG-PET Scans: Comparison with Visual AssessmentMolecular Imaging and Biology, 2009