Semi-Automated Determination of Heavy Metals in Autopsy Tissue Using Robot-Assisted Sample Preparation and ICP-MS
Open Access
Abstract
The endoprosthetic care of hip and knee joints introduces multiple materials into the human body. Metal containing implant surfaces release degradation products such as particulate wear and corrosion debris, metal-protein complexes, free metallic ions, inorganic metal salts or oxides. Depending on the material composition of the prostheses, a systemic exposure occurs and may result in increasing metal concentrations in body fluids and tissues especially in the case of malfunctions of the arthroplasty components. High concentrations of Cr, Co, Ni, Ti and Al affect multiple organs such as thyroid, heart, lung and cranial nerves and may lead to metallosis, intoxications, poly-neuropathy, retinopathy, cardiomyopathy and the formation of localized pseudo tumors. The determination of the concentration of metals in body fluids and tissues can be used for predicting failure of hip or knee replacements to prevent subsequent severe intoxications. A semi-automated robot-assisted measurement system is presented for the determination of heavy metals in human tissue samples using inductively coupled plasma mass spectrometry (ICP-MS). The manual and automated measurement processes were similarly validated using certified reference material and the results are compared and discussed. The automation system was successfully applied in the determination of heavy metals in human tissue; the first results are presented.Keywords
Funding Information
- Deutsche Arthrosehilfe (P481-A30-Mittelmeier-EP2-lutt1-hüfte-en-CCS-29k-2020-23)
This publication has 32 references indexed in Scilit:
- Sample preparation methods for determination of Cd, Pb and Sn in meat samples by GFAAS: use of acid digestion associated with a cold finger apparatus versus solubilization methodsAnalytical Methods, 2013
- Evaluation of the Method for Analyzing Chromium, Cobalt and Titanium Ion Levels in the Blood Following Hip Replacement with a Metal-on-Metal ProsthesisJournal of Analytical Toxicology, 2012
- Cobalt and Chromium Ion Release After Large-Diameter Metal-on-Metal Total Hip ArthroplastyThe Journal of Arthroplasty, 2012
- Local and systemic toxicity of nanoscale debris particles in total hip arthroplastyJournal of Applied Toxicology, 2012
- Characterization of metal-wear nanoparticles in pseudotumor following metal-on-metal hip resurfacingNanomedicine: Nanotechnology, Biology and Medicine, 2011
- Evaluation of cadmium, lead, nickel and zinc status in biological samples of smokers and nonsmokers hypertensive patientsJournal of Human Hypertension, 2009
- High-resolution ICP–MS determination of Ti, V, Cr, Co, Ni, and Mo in human blood and urine of patients implanted with a hip or knee prosthesisAnalytical and Bioanalytical Chemistry, 2008
- Concentrations of Cd, Co, Cu, Fe, Mn, Rb, V, and Zn in Formalin-Fixed Brain Tissue in Amyotrophic Lateral Sclerosis and Parkinsonism-Dementia Complex of Guam Determined by High-Resolution ICP-MSBiological Trace Element Research, 2003
- Changes of concentrations of the elements Co, Cr, Sb, and Sc in tissues of persons with joint implantsBiological Trace Element Research, 1994
- Spectral interferences encountered in the analysis of biological materials by inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1994