Real-Time Hypoglycemia Detection from Continuous Glucose Monitoring Data of Subjects with Type 1 Diabetes
- 1 July 2013
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 15 (7) , 538-543
Abstract
Background: Hypoglycemia is a potentially fatal condition. Continuous glucose monitoring (CGM) has the potential to detect hypoglycemia in real time and thereby reduce time in hypoglycemia and avoid any further decline in blood glucose level. However, CGM is inaccurate and shows a substantial number of cases in which the hypoglycemic event is not detected by the CGM. The aim of this study was to develop a pattern classification model to optimize real-time hypoglycemia detection. Materials and Methods: Features such as time since last insulin injection and linear regression, kurtosis, and skewness of the CGM signal in different time intervals were extracted from data of 10 male subjects experiencing 17 insulin-induced hypoglycemic events in an experimental setting. Nondiscriminative features were eliminated with SEPCOR and forward selection. The feature combinations were used in a Support Vector Machine model and the performance assessed by sample-based sensitivity and specificity and event-based sensitivity and number of false-positives. Results: The best model was composed by using seven features and was able to detect 17 of 17 hypoglycemic events with one false-positive compared with 12 of 17 hypoglycemic events with zero false-positives for the CGM alone. Lead-time was 14 min and 0 min for the model and the CGM alone, respectively. Conclusions: This optimized real-time hypoglycemia detection provides a unique approach for the diabetes patient to reduce time in hypoglycemia and learn about patterns in glucose excursions. Although these results are promising, the model needs to be validated on CGM data from patients with spontaneous hypoglycemic events.Keywords
This publication has 24 references indexed in Scilit:
- Use of Subcutaneous Interstitial Fluid Glucose to Estimate Blood Glucose: Revisiting Delay and Sensor OffsetJournal of Diabetes Science and Technology, 2010
- Statement by the American Association of Clinical Endocrinologists Consensus Panel on Continuous Glucose MonitoringEndocrine Practice, 2010
- Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose MonitorsDiabetes Care, 2008
- High Frequency of Unrecognized Hypoglycaemias in Patients with Type 2 Diabetes is Discovered by Continuous Glucose MonitoringExperimental and Clinical Endocrinology & Diabetes, 2007
- Alarms Based on Real-Time Sensor Glucose Values Alert Patients to Hypo- and Hyperglycemia: The Guardian Continuous Monitoring SystemDiabetes Technology & Therapeutics, 2004
- The Continuous Glucose Monitoring System Is Useful for Detecting Unrecognized Hypoglycemias in Patients With Type 1 and Type 2 Diabetes but Is Not Better Than Frequent Capillary Glucose Measurements for Improving Metabolic ControlDiabetes Care, 2003
- Hypoglycaemia: The limiting factor in the glycaemic management of Type I and Type II Diabetes*Diabetologia, 2002
- Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)The Lancet, 1998
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusThe New England journal of medicine, 1993
- Emotional attitudes in adult insulin-dependent diabeticsJournal of Psychosomatic Research, 1975