Exploring and validating heating dynamics in a radio-frequency electromagnetic field-based resonant chamber for mouse hyperthermia research
- 10 June 2024
- journal article
- research article
- Published by Taylor & Francis in Electromagnetic Biology and Medicine
- Vol. 43 (3) , 164-175
Abstract
Mild whole-body hyperthermia has been shown to have anti-tumor effects through an immune-modulating mechanism. Before it is widely applied in the clinic, tremendous mechanistic research in animals is necessary to adhere to evidence-based principles. The radio frequency electromagnetic field (RF-EMF) based heating facility could be a good choice for hyperthermia treatment, but the heating characteristics of a facility, including structure design, electromagnetic and thermal dosimetry, and the biologic effects of hyperthermia, need to be well elucidated. Here, we reported the heating characteristic study on a resonant chamber (RC) excited by a 1800 MHz solid source. The EMF in the RC was stirred by 24 static reflectors, which resulted in the standard deviation of electric field intensity being below 3 dB in the EM homogeneity evaluation. For the exposure scenario, six free-moving mice were loaded into separate cases and exposed simultaneously in the RC. The EMF energy absorption and distribution in exposed mice were calculated with the 12-plane-waves method of numerical simulation. Different levels of core body temperature increment in exposed mice were achieved through regulation of the source output power. Overexpression of heat shock proteins (HSPs) was detected in the liver, lung and muscle, but not in the brain of the exposed mice. The levels of representative inflammatory cytokines in the serum, TNF-alpha and IL-10 increased post RC exposure. Based on the heating characteristic study and validation, the applied RC would be a qualified heating system for mild whole-body hyperthermia effect research in mice. Mild whole-body hyperthermia has potential anti-tumor effects by modulating the immune system. A radio frequency electromagnetic field (RF-EMF)-based heating facility emerges as a suitable option for hyperthermia treatment. However, a qualified heating facility for scientific research must elucidate its heating characteristics and validate the biological effects associated with hyperthermia. In this study, we report the characteristics of a rodent heating chamber using EMF energy. The special structure of the chamber not only achieved efficient EMF usage but also ensured the homogeneity in EMF spatial distribution, animal EM absorption, and EMF-caused biological effects. Our work may offer insights for designing a low-cost yet reliable heating facility for scientific research.Keywords
Funding Information
- National Natural Science Foundation of China (No. 82273604)
- Key Laboratory of Electromagnetic Radiation Protection
- Innovation Project Grants of Army Medical University, China (2019XYY01)
This publication has 33 references indexed in Scilit:
- Evaluating the biological safety on mice at 16 T static magnetic field with 700 MHz radio-frequency electromagnetic fieldEcotoxicology and Environmental Safety, 2022
- Protocol for fever-range whole-body hyperthermia (WBH) in mice to study febrile effect on T-cell adhesion and migrationSTAR Protocols, 2021
- Effect of Exposure to a Radiofrequency Electromagnetic Field on Body Temperature in Anesthetized and Non‐Anesthetized RatsBioelectromagnetics, 2019
- Evaluation of the genotoxicity of cell phone radiofrequency radiation in male and female rats and mice following subchronic exposureEnvironmental and Molecular Mutagenesis, 2019
- Desktop exposure system and dosimetry for small scale in vivo radiofrequency exposure experimentsBioelectromagnetics, 2015
- Association of glucocorticoid with stress-induced modulation of body temperature, blood glucose and innate immunityPsychoneuroendocrinology, 2009
- Radio frequency electromagnetic fields: mild hyperthermia and safety standards2007
- Methodology of detailed dosimetry and treatment of uncertainty and variations for in vivo studiesBioelectromagnetics, 2006
- Hyperthermia in combined treatment of cancerThe Lancet Oncology, 2002
- Empirical validation of SAR values predicted by FDTD modeling*†Bioelectromagnetics, 2001