Implications of lowering threshold of plasma troponin concentration in diagnosis of myocardial infarction: cohort study

Authors:

Abstract
Objective To assess the relation between troponin concentration, assay precision, and clinical outcomes in patients with suspected acute coronary syndrome. Design Cohort study. Setting Tertiary centre in Scotland. Participants 2092 consecutive patients admitted with suspected acute coronary syndrome were stratified with a sensitive troponin I assay into three groups (Main outcome measure One year survival without events (recurrent myocardial infarction, death) in patients grouped by troponin concentration. Results Troponin I concentrations were v 3%, PConclusion Lowering the diagnostic threshold to the 99th centile and accepting greater assay imprecision would identify more patients with acute coronary syndrome at risk of recurrent myocardial infarction and death but would increase the diagnosis of myocardial infarction by 47%. It remains to be established whether reclassification of these patients and treatment for myocardial infarction would improve outcome.

This publication has 25 references indexed in Scilit: