Abolition of Respiratory-Motion Artifact in Computed Tomography Coronary Angiography with Ultrafast Examinations: A Comparison between 64-row and 320-row Multidetector Scanners
Open Access
- 1 February 2010
- journal article
- research article
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 61 (1) , 5-12
Abstract
Purpose: To compare the incidence of respiratory artifact in computed tomography (CT) coronary angiography performed with 64-row and 320-row multidetector scanners and to assess its effect on coronary evaluability. Methods: A retrospective review of consecutive coronary angiograms performed on a 64-row multidetector CT from March to April 2007 (group 1: 115 patients, 63 men; mean age [standard deviation] 59.6 ± 12.8 years) and on a 320-row multidetector CT from March to April 2008 (group 2: 169 patients, 89 men; mean [SD] age 57.9 ± 11.6 years). Two cardiac radiologists assessed the occurrence of respiratory artifact and coronary evaluability in studies with respiratory artifacts. Unevaluable coronary segments because of motion at the same anatomical level of the respiratory artifact were considered unevaluable because of this artifact. The association between the occurrence of respiratory artifact and patient biometrics, medication, and scan parameters was examined. Results: Respiratory artifacts were detected in 9 of the 115 patients from group 1 (7.8%) and in none of the 169 patients from group 2 ( P < .001). Group 1 had longer scan times (median, 9.3 seconds; range, 7.5−14.4 seconds) compared with group 2 (median, 1.5 seconds; range, 1.1−3.5 seconds; P < .001). In group 1, 4 patients (3.5%) showed unevaluable coronary segments because of respiratory artifacts, and the CT coronary angiography was repeated in 1 patient (0.9%). Conclusions: Respiratory artifacts are important in CT coronary angiography performed with 64-row multidetector scanners and impair the diagnostic utility of the examination in up to 3.5% of the studies. These artifacts can be virtually eliminated with a faster scan time provided by 320-row multidetector CT.Keywords
This publication has 25 references indexed in Scilit:
- Letter to the Editor: re: Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering.European Radiology, 2009
- Prospective versus Retrospective ECG Gating for 64-Detector CT of the Coronary Arteries: Comparison of Image Quality and Patient Radiation DoseRadiology, 2008
- Cardiac Multidetector CT: Technical and Diagnostic Evaluation with Evidence-based Practice TechniquesRadiology, 2008
- Initial evaluation of coronary images from 320-detector row computed tomographyThe International Journal of Cardiovascular Imaging, 2008
- 64-multislice detector computed tomography coronary angiography as potential alternative to conventional coronary angiography: a systematic review and meta-analysisEuropean Heart Journal, 2007
- Accuracy of 16-Row Multidetector Computed Tomography for the Assessment of Coronary Artery StenosisJAMA, 2006
- Quantitative parameters of image quality in 64-slice computed tomography angiography of the coronary arteriesEuropean Journal of Radiology, 2006
- Improvement of Image Quality with ß-Blocker Premedication on ECG-Gated 16-MDCT Coronary AngiographyAmerican Journal of Roentgenology, 2005
- Pitfalls, Artifacts, and Remedies in Multi– Detector Row CT Coronary AngiographyRadioGraphics, 2004
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975