Comparison of synthetic mammography, reconstructed from digital breast tomosynthesis, and digital mammography: evaluation of lesion conspicuity and BI-RADS assessment categories
- 17 August 2017
- journal article
- clinical trial
- Published by Springer Nature in Breast Cancer Research and Treatment
- Vol. 166 (3) , 765-773
Abstract
Purpose To compare the interpretive performance of synthetic mammography (SM), reconstructed from digital breast tomosynthesis (DBT), and full-field digital mammography (FFDM) in a diagnostic setting, covering different conditions of breast density and mammographic signs. Methods A retrospective analysis was conducted on 231 patients, who underwent FFDM and DBT (from which SM images were reconstructed) between September 2014–September 2015. The study included 250 suspicious breast lesions, all biopsy proven: 148 (59.2%) malignant and 13 (5.2%) high-risk lesions were confirmed by surgery, 89 (35.6%) benign lesions had radiological follow-up. Two breast radiologists, blinded to histology, independently reviewed all cases. Readings were performed with SM alone, then with FFDM, collecting data on: probability of malignancy for each finding, lesion conspicuity, mammographic features and dimensions of detected lesions. Results Agreement between readers was good for BI-RADS classification (Cohen’s k-coefficient = 0.93 ± 0.02) and for lesion dimension (Wilcoxon’s p = 0.76). Visibility scores assigned to SM and FFDM for each lesion were similar for non-dense and dense breasts, however, there were significant differences (p = 0.0009) in distribution of mammographic features subgroups. SM and FFDM had similar sensitivities in non-dense (respectively 94 vs. 91%) and dense breasts (88 vs. 80%) and for all mammographic signs (93 vs. 87% for asymmetric densities, 96 vs. 75% for distortion, 92 vs. 85% for microcalcifications, and both 94% for masses). Based on all data, there was a significant difference in sensitivity for SM (92%) vs. FFDM (87%), p = 0.02, whereas the two modalities yielded similar results for specificity (SM: 60%, FFDM: 62%, p = 0.21). Conclusions SM alone showed similar interpretive performance to FFDM, confirming its potential role as an alternative to FFDM in women having tomosynthesis, with the added advantage of halving the patient’s dose exposure.Keywords
Funding Information
- National Breast Cancer Foundation (NBCF, Australia) Breast Cancer Research Leadership Fellowship
This publication has 20 references indexed in Scilit:
- Rapid review: Estimates of incremental breast cancer detection from tomosynthesis (3D-mammography) screening in women with dense breastsThe Breast, 2016
- Breast Cancer Screening Using Tomosynthesis and Digital Mammography in Dense and Nondense BreastsJAMA, 2016
- Digital Breast Tomosynthesis: State of the ArtRadiology, 2015
- Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammographyThe Breast, 2015
- Breast Cancer Screening Using Tomosynthesis in Combination With Digital MammographyJAMA, 2014
- Clinical Implementation of Digital Breast TomosynthesisRadiologic Clinics of North America, 2014
- Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison studyThe Lancet Oncology, 2013
- Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening ProgramRadiology, 2013
- Overview of the evidence on digital breast tomosynthesis in breast cancer detectionThe Breast, 2013
- A review of breast tomosynthesis. Part I. The image acquisition processMedical Physics, 2013