Quantitative myocardial perfusion by O-15-water PET: individualized vs. standardized vascular territories
Authors:
- Anders ThomassenATAnders Thomassen
- Henrik PetersenHPHenrik Petersen
- Allan JohansenAJAllan Johansen
- Poul-Erik BraadPBPoul-Erik Braad
- Axel Cosmus Pyndt DiederichsenADAxel Cosmus Pyndt Diederichsen
- Hans MickleyHMHans Mickley
- Lisette Okkels JensenLJLisette Okkels Jensen
- Oke GerkeOke Gerke
- Jane Angel SimonsenJSJane Angel Simonsen
- Poul Flemming Høilund-CarlsenPoul Flemming Høilund-Carlsen
Open Access
- 5 May 2015
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 16 (9) , jev111-6
Abstract
Aims Reporting of quantitative myocardial blood flow (MBF) is typically performed in standard coronary territories. However, coronary anatomy and myocardial vascular territories vary among individuals, and a coronary artery may erroneously be deemed stenosed or not if territorial demarcation is incorrect. So far, the diagnostic consequences of calculating individually vs. standardly assessed MBF values have not been reported. We examined whether individual reassignment of vascular territories would improve the diagnostic accuracy of MBF with regard to the detection of significant coronary artery disease (CAD). Methods and results Forty-four patients with suspected CAD were included prospectively and underwent coronary CT-angiography and quantitative MBF assessment with O-15-water PET followed by invasive, quantitative coronary angiography, which served as reference. MBF was calculated in the vascular territories during adenosine stress according to a standardized 17-segment American Heart Association model and an individualized model, using CT-angiography to adjust the coronary territories to their feeding vessels. Individually defined territories deviated from standard territories in 52% of patients. However, MBF in the three coronary territories defined by standard and individualized models did not differ significantly, except in one patient, in whom the MBF of an individualized coronary territory deviated sufficiently as to change the test from a false positive to a true negative result in this particular territory. Conclusion Disparity between standardized and individualized vascular territories was present in half of the patients, but had little clinical impact. Still, caution should be taken not always to rely on standard territories, as this may at times cause misinterpretation.Keywords
This publication has 30 references indexed in Scilit:
- Definition of Vascular Territories on Myocardial Perfusion Images by Integration with True Coronary Anatomy: A Hybrid PET/CT AnalysisJournal of Nuclear Medicine, 2010
- Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiographyJournal of Nuclear Cardiology, 2009
- Diagnostic value of cardiac 64-slice computed tomography: Importance of coronary calciumScandinavian Cardiovascular Journal, 2009
- Quantification of myocardial hypoperfusion with 99mTc-sestamibi in patients undergoing prolonged coronary artery balloon occlusionNuclear Medicine Communications, 2002
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002
- Assessment of myocardial area at risk by technetium-99m sestamibi during coronary artery occlusion: comparison between three tomographic methods of quantificationEuropean Journal of Nuclear Medicine and Molecular Imaging, 1996
- Simultaneous assessment of myocardial perfusion and left ventricular function during transient coronary occlusionJACC, 1995
- Assessment of the extent of jeopardized myocardium during acute coronary artery occlusion followed by reperfusion in man using technetium-99m isonitrile imagingAmerican Heart Journal, 1991
- Assessment of regional myocardial perfusion with thallium imaging during transient left anterior descending coronary arterial occlusion during angioplastyThe American Journal of Cardiology, 1986
- Changes in collateral channel filling immediately after controlled coronary artery occlusion by an angioplasty balloon in human subjectsJACC, 1985