Determination of cadmium and zinc isotope ratios in sheep's blood and organ tissue by electrothermal vaporization inductively coupled plasma mass spectrometry. Invited lecture
Authors:
- D. Conrad GrégoireDGD. Conrad Grégoire
- Julian LeeJLJulian Lee
- 1 January 1994
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 9 (3) , 393-397
Abstract
A method is described for the determination of Cd and Zn isotope ratios in sheep's blood and organ tissue. Samples were digested with nitric acid using a microwave oven. Cadmium and Zn were separated from matrix components using adsorption chromatography prior to isotope ratio measurement by electrothermal vaporization inductively coupled plasma mass spectrometry. A concentration factor of 35 was achieved. Limits of detection for the determination of Cd and Zn in blood were 0.34 and 0.40 pg g–1, respectively. Cadmium isotope ratios (111Cd: 106Cd; 111Cd: 110Cd) were determined with a precision of 2–3% for both peak height and area count measurements. Zinc isotope ratios (68Zn: 67Zn; 68Zn: 66Zn) were determined with a precision of 2% for peak height measurements and 1% for peak area count measurements.Keywords
This publication has 19 references indexed in Scilit:
- Determination of ultratrace levels of heavy metals in arctic snow by electrothermal vaporization inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1993
- Measurement of boron concentration and isotope ratios in biological samples by inductivey coupled plasma mass spectrometry with direct injection nebulizationAnalytica Chimica Acta, 1991
- A kinetic model of copper metabolism in lactating dairy cowsCanadian Journal of Animal Science, 1991
- True absorption of selenium in dairy cows: Stable isotope tracer methodology and effect of dietary copperCanadian Journal of Animal Science, 1991
- Measurements of total lead concentrations and of lead isotope ratios in whole blood by use of inductively coupled plasma source mass spectrometryJournal of Analytical Atomic Spectrometry, 1988
- Optimisation of instrumental parameters for the precise measurement of isotope ratios with inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1988
- Measurement of stable isotopes of bromine in biological fluids with inductively coupled plasma mass spectrometryThe Analyst, 1988
- Erythrocyte incorporation of ingested stable isotope of iron (58Fe)American Journal of Hematology, 1986
- Isotope ratio determinations by inductively coupled plasma/mass spectrometry for zinc bioavailability studiesAnalytica Chimica Acta, 1986
- Isotopic Abundances and Atomic Weights of the ElementsJournal of Physical and Chemical Reference Data, 1984