Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
Open Access
- 1 January 2012
- journal article
- Published by Korean Society of Otorhinolaryngology-Head and Neck Surgery in Clinical and Experimental Otorhinolaryngology
- Vol. 5 (4) , 194-200
Abstract
The stimulation levels programmed in cochlear implant systems are affected by an evolution since the first switch-on of the processor. This study was designed to evaluate the changes in stimulation levels over time and the relationship between post-implantation physiological changes and with the hearing experience provided by the continuous use of the cochlear implant. Sixty-two patients, ranging in age from 4 to 68 years at the moment of implantation participated in this study. All subjects were implanted with the 12 channels COMBI 40+ cochlear implant at San Cecilio University Hospital, Granada, Spain. Hearing loss etiology and progression characteristics varied across subjects. The analyzed programming maps show that the stimulation levels suffer a fast evolution during the first weeks after the first switch-on of the processor. Then, the evolution becomes slower and the programming parameters tend to be stable at about 6 months after the first switch-on. The evolution of the stimulation levels implies an increment of the electrical dynamic range, which is increased from 15.4 to 20.7 dB and improves the intensity resolution. A significant increment of the sensitivity to acoustic stimuli is also observed. For some patients, we have also observed transitory changes in the electrode impedances associated to secretory otitis media, which cause important changes in the programming maps. We have studied the long-term evolution of the stimulation levels in cochlear implant patients. Our results show the importance of systematic measurements of the electrode impedances before the revision of the programming map. This report also highlights that the evolution of the programming maps is an important factor to be considered in order to determine an adequate calendar fitting of the cochlear implant processor.Keywords
This publication has 17 references indexed in Scilit:
- Using Evoked Compound Action Potentials to Assess Activation of Electrodes and Predict C-Levels in the Tempo+ Cochlear Implant Speech ProcessorEar & Hearing, 2010
- Relation of Electrically Evoked Compound Action Potential Thresholds to Behavioral T- and C-Levels in Children with Cochlear ImplantsEar & Hearing, 2009
- Use of Neural Response Telemetry Measures to Objectively Set the Comfort Levels in the Nucleus 24 Cochlear ImplantJournal of the American Academy of Audiology, 2006
- Comparisons between Neural Response Imaging thresholds, electrically evoked auditory reflex thresholds and most comfortable loudness levels in CII Bionic Ear users with HiResolution™ sound processing strategiesActa Oto-Laryngologica, 2005
- Changes over time in electrical stimulation levels and electrode impedance values in children using the Nucleus 24M cochlear implantInternational Journal of Pediatric Otorhinolaryngology, 2003
- A Longitudinal Study of Electrode Impedance, the Electrically Evoked Compound Action Potential, and Behavioral Measures in Nucleus 24 Cochlear Implant UsersEar & Hearing, 2001
- Mimicking the human earIEEE Signal Processing Magazine, 1998
- Electrical middle ear muscle reflex: Use in cochlear implant programmingOtolaryngology–Head and Neck Surgery, 1997
- Better speech recognition with cochlear implantsNature, 1991
- THE SIGNIFICANCE OF THE DIFFERENCE BETWEEN TWO MEANS WHEN THE POPULATION VARIANCES ARE UNEQUALBiometrika, 1938