Automatic Adjustment of Pacing Parameters Based on Intracardiac Impedance Measurements
Author:
- 1 December 1990
- journal article
- review article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 13 (12) , 1702-1710
Abstract
SCHALDACH, M.: Automatic Adjustment of Pacing Parameters Based on Intracardiac Impedance Measurements.The selection of the parameters used for rate control is determined not only by technical feasibility, but also by patient considerations. Technical feasibility considerations include long‐term stability and reliability of the sensor, as well as susceptibility to interference. The patient considerations relate to the patient's physical state, including the various physiological and pathologic conditions. The rate response must be in proportion to circulatory demand. The specificity of the rate response is of particular importance for the patient with low cardiac reserve. The development of future pacemakers aims at providing additional patient benefits, with a reduction of the effort associated with initial parameter selection and patient follow‐up. This will be achieved by utilizing a better understanding of the integration of the control mechanisms for the entire cardiovascular system under physiological and pathological conditions. To support the development of the future pacemakers, we must utilize realistic multiparametric models of the cardiovascular system. These models will assist the evaluation of potential algorithms for integrating multisensor signals into a single pacing rate. The parameterization and validation of these models are important issues to be addressed. Intracardiac impedance measurements in conjunction with microprocessor controlled signal processing and improved lead technology provide a great variety of practical applications for physiological control of the pacing rate and the automatic adjustment of pacemaker parameters. The concepts of an “intelligent” pacemaker capable of automatic control in response to changes in the pacing requirements under a variety of physiological and clinical conditions are presented.Keywords
This publication has 22 references indexed in Scilit:
- Bewegungsenergie als Steuergröße für die Anpassung der Stimulationsfrequenz - Motion Energy as a Control Variable for Sensor-Driven Rate AdaptationBiomedical Engineering / Biomedizinische Technik, 1989
- PEP-gesteuerter Herzschrittmacher - Pacemaker with PEP-ControlIed Rate AdaptationBiomedical Engineering / Biomedizinische Technik, 1989
- Physiological Principles of a New Method for Rate Responsive Pacing Using the Pre‐ejection IntervalPacing and Clinical Electrophysiology, 1988
- A New Multisensor Pacing System Using Stroke Volume, Respiratory Rate, Mixed Venous Oxygen Saturation, And Temperature, Right Atrial Pressure, Right Ventricular Pressure, And dP/dtPacing and Clinical Electrophysiology, 1988
- Frequenzadaption eines künstlichen Herzschrittmachers über einen Volumenregelkreis - Rate Adaptive Pacemaker Uselying Intracardiac Volume for Closed Loop ControlBiomedical Engineering / Biomedizinische Technik, 1988
- Sensors in PacingPacing and Clinical Electrophysiology, 1986
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984
- Systolic time intervals reconsideredThe American Journal of Cardiology, 1984
- Respiratory Rate as a Determinant of Optimal Pacing RatePacing and Clinical Electrophysiology, 1983
- Central Body Temperature as a Guide to Optimal Heart RatePacing and Clinical Electrophysiology, 1983