A standard system phantom for magnetic resonance imaging
Open Access
- 13 April 2021
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (3) , 1194-1211
Abstract
Purpose: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal‐to‐noise ratio (SNR), proton‐spin relaxation times, image uniformity and proton density.Methods: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57‐element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice‐profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T1 and T2 mapping, image resolution, slice profile, and SNR.Results: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions.Conclusions: A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.Keywords
This publication has 25 references indexed in Scilit:
- Optimization and validation of methods for mapping of the radiofrequency transmit field at 3TMagnetic Resonance in Medicine, 2010
- Extensive NMRD studies of Ni(II) salt solutions in water and water–glycerol mixturesJournal of Magnetic Resonance, 2008
- Imaging as a BiomarkerAcademic Radiology, 2008
- Relaxation times of breast tissue at 1.5T and 3T measured using IDEALJournal of Magnetic Resonance Imaging, 2005
- Central brightening due to constructive interference with, without, and despite dielectric resonanceJournal of Magnetic Resonance Imaging, 2005
- In vivo 1H2O T measurement in the human occipital lobe at 4T and 7T by Carr‐Purcell MRI: Detection of microscopic susceptibility contrastMagnetic Resonance in Medicine, 2002
- Estimation of the iron concentration in excised gray matter by means of proton relaxation measurementsMagnetic Resonance in Medicine, 1996
- An MRI phantom material for quantitative relaxometryMagnetic Resonance in Medicine, 1987
- Errors in the measurements of T2 using multiple‐echo MRI techniques. I. Effects of radiofrequency pulse imperfectionsMagnetic Resonance in Medicine, 1986
- Errors in measurements of transverse relaxation ratesJournal of Magnetic Resonance (1969), 1973