Four‐dimensional single breathhold magnetic resonance imaging using kt‐BLAST enables reliable assessment of left‐ and right‐ventricular volumes and mass
Open Access
- 8 March 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 25 (4) , 737-742
Abstract
Purpose: To prospectively determine the accuracy of four‐dimensional (4D) kt‐broad‐use linear acquisition speed‐up technique (BLAST) accelerated MRI (kt‐BLAST) for the assessment of left‐ventricular (LV) volumes and mass as well as right‐ventricular (RV) volumes in comparison to standard multiple breathhold cine imaging.Materials and Methods: A total of 40 patients with suspected or known coronary artery disease (CAD) underwent cardiac MRI. In each patient a standard multislice cine steady‐state free precession (SSFP) sequence was performed with complete ventricular coverage during multiple breathholds. Additionally, a kt‐BLAST‐accelerated 4D sequence with complete ventricular coverage was acquired during one single breathhold. For comparison of SSFP and kt‐BLAST, the following LV parameters were determined: end‐diastolic and end‐systolic volumes, ejection fraction, end‐diastolic diameter and mass. For comparison of RV dimensions, end‐diastolic and end‐systolic volumes and ejection fraction were assessed.Results: LV volumes, ejection fraction, diameter, and mass showed a strong correlation between SSFP and kt‐BLAST (r = 0.98–0.99; P < 0.01). In addition, RV parameters demonstrated a high correlation (r = 0.97–0.98; P < 0.01). For all parameters, the calculated bias between both methods was found to be minimal (0.4–4%).Conclusion: 4D kt‐BLAST‐accelerated MRI enabled the accurate assessment of LV and RV quantitative parameters during one single breathhold when compared to standard multislice, multiple breathhold SSFP imaging. J. Magn. Reson. Imaging 2007.Keywords
This publication has 21 references indexed in Scilit:
- Optimizing spatiotemporal sampling for k‐t BLAST and k‐t SENSE: Application to high‐resolution real‐time cardiac steady‐state free precessionMagnetic Resonance in Medicine, 2005
- Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report?European Heart Journal, 2004
- k‐t BLAST and k‐t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlationsMagnetic Resonance in Medicine, 2003
- Normal Human Right and Left Ventricular Mass, Systolic Function, and Gender Differences by Cine Magnetic Resonance ImagingJournal of Cardiovascular Magnetic Resonance, 1999
- Quantification of right ventricular function with magnetic resonance imaging in children with normal hearts and with congenital heart diseaseAmerican Heart Journal, 1995
- Estimation of human myocardial mass with MR imaging.Radiology, 1988
- In Vivo Validation of MR Velocity ImagingJournal of Computer Assisted Tomography, 1987
- Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging.Radiology, 1987
- Left ventricular volumes measured by MR imaging.Radiology, 1985
- DIMENSIONAL ACCURACY OF MAGNETIC RESONANCE IN STUDIES OF THE HEARTThe Lancet, 1985