Abstract
Partial wetting has been recently proposed to facilitate the operation of microresonators with high quality factor in liquids. By applying this concept to a resonator operated in a shearing eigenmode, a further reduction of viscous damping is expected corresponding to theory. In this study, an excellent quality factor of 490 could be verified for suspended plate-microresonators operated in water combining these two approaches. As a proof of concept, the resonators were employed as mass sensors in water revealing a sensitivity of 80 Hz/pg.

This publication has 11 references indexed in Scilit: