Water absorption and hygrothermal ageing of ultraviolet cured glass‐fiber reinforced acrylate composites
- 24 May 2012
- journal article
- research article
- Published by Wiley in Polymer Composites
- Vol. 33 (7) , 1120-1128
Abstract
In this article, an ultraviolet curable glass fiber reinforced polymer (UV‐GFRP) composite developed for fast repair or strengthening of concrete structures, was investigated on its water absorption and hygrothermal ageing behaviors. Cured UV‐GFRP coupons were subjected to immersion in distilled water or concrete pore solution (pH value around 13) for 4–8 months at room temperature and elevated temperatures (40 and 60°C), respectively. Water absorption and thermomechanical properties of the samples were tested as a function of immersion time. Water uptake curves of UV‐GFRP exposed to elevated temperatures and/or alkaline solutions show serious mass loss. Debonding of fibers from resin matrix brought in increased coefficient of diffusion along fiber directions, due to the capillary effect. After 4 months of immersion in both media, the tensile strength of UV‐GFRP was deteriorated remarkably, while the tensile modulus was less affected. According to Arrhenius equation, the tensile strength of UV‐GFRP is predicted to remain 77.6% of its original value after50 years when immersed in water at 20°C, but only 24.5% left in the case of alkaline solution. This suggests that the present UV‐GFRP system does not suit for the application in strong alkaline environments. POLYM. COMPOS., 2012. © 2012 Society of Plastics EngineersKeywords
This publication has 21 references indexed in Scilit:
- Fabrication and mechanical properties of UV-curable glass fiber-reinforced polymer—matrix compositeJournal of Composite Materials, 2010
- Resin hardness and interlaminar shear strength of a glass-fibre/vinylester composite cured with high intensity ultraviolet (UV) lightJournal of Materials Science, 2009
- Hygrothermal effects on high VF pultruded unidirectional carbon/epoxy composites: Moisture uptakeComposites Part B: Engineering, 2009
- Mechanical properties and styrene emission levels of a UV-cured glass-fibre/vinylester compositeComposite Structures, 2008
- Segmental relaxation of water-aged ambient cured epoxyPolymer Degradation and Stability, 2007
- UV-cured FRP joint thickness effect on coupled composite pipesComposite Structures, 2007
- DMTA based investigation of hygrothermal ageing of an epoxy system used in rehabilitationJournal of Applied Polymer Science, 2007
- Design factors, reliability, and durability prediction of wet layup carbon/epoxy used in external strengtheningComposites Part B: Engineering, 2007
- Fast repair of damaged RC beams using UV curing FRP compositesComposite Structures, 2006
- Repair of damaged RC columns using fast curing FRP compositesComposites Part B: Engineering, 2003