Tests of Fixed-Ended Plain Channel Columns
- 1 February 1998
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 124 (2) , 131-139
Abstract
The paper describes a test program on cold-formed plain channel columns compressed between fixed ends and pinned ends. Whereas it is well-known that local buckling of pin-ended channel columns induces overall bending, this phenomenon does not occur in fixed-ended channel columns that remain straight after local buckling and only bend when overall buckling occurs. These fundamentally different effects of local buckling on the behavior of pin-ended and fixed-ended channel sections lead to inconsistencies in traditional design approaches, which account for full or partial rotational end restraint solely by using effective lengths. A series of tests was performed for different geometries of cross section fabricated by brake pressing from high-strength steel sheet. Tests were performed over a range of lengths such that the column curve could be obtained. Local buckling loads were also obtained from the fixed-ended column tests. Detailed measurements of local and overall geometric imperfections, material proper...Keywords
This publication has 6 references indexed in Scilit:
- Bifurcation of locally buckled membersThin-Walled Structures, 1997
- Bifurcation of singly symmetric columnsThin-Walled Structures, 1997
- Design of thin-walled columns with unstiffened flangesEngineering Structures, 1994
- Design of thin-walled plain channel section columns against flexural bucklingThin-Walled Structures, 1994
- The flexural behaviour of fixed-ended channel section columnsThin-Walled Structures, 1993
- Local, Distortional, and Lateral Buckling of I-BeamsJournal of the Structural Division, 1978