Abstract
The paper describes a test program on cold-formed plain channel columns compressed between fixed ends and pinned ends. Whereas it is well-known that local buckling of pin-ended channel columns induces overall bending, this phenomenon does not occur in fixed-ended channel columns that remain straight after local buckling and only bend when overall buckling occurs. These fundamentally different effects of local buckling on the behavior of pin-ended and fixed-ended channel sections lead to inconsistencies in traditional design approaches, which account for full or partial rotational end restraint solely by using effective lengths. A series of tests was performed for different geometries of cross section fabricated by brake pressing from high-strength steel sheet. Tests were performed over a range of lengths such that the column curve could be obtained. Local buckling loads were also obtained from the fixed-ended column tests. Detailed measurements of local and overall geometric imperfections, material proper...

This publication has 6 references indexed in Scilit: