XPOL-III: a New-Generation VLSI CMOS ASIC for High-Throughput X-ray Polarimetry
Authors:
- M. MinutiMMM. Minuti
- L. BaldiniLBL. Baldini
- R. BellazziniRBR. Bellazzini
- A. BrezABA. Brez
- M. CeccantiMCM. Ceccanti
- F. KrummenacherFKF. Krummenacher
- L. LatronicoLLL. Latronico
- L. LucchesiLLL. Lucchesi
- A. ManfredaAMA. Manfreda
- L. OrsiniLOL. Orsini
- M. PincheraMPM. Pinchera
- A. ProfetiAPA. Profeti
Preprint
Abstract
While the successful launch and operation in space of the Gas Pixel Detectors onboard the PolarLight cubesat and the Imaging X-ray Polarimetry Explorer demonstrate the viability and the technical soundness of this class of detectors for astronomical X-ray polarimetry, it is clear that the current state of the art is not ready to meet the challenges of the next generation of experiments, such as the enhanced X-ray Timing and Polarimetry mission, designed to allow for a significantly larger data throughput. In this paper we describe the design and test of a new custom, self-triggering readout ASIC, dubbed XPOL-III, specifically conceived to address and overcome these limitations. While building upon the overall architecture of the previous generations, the new chip improves over its predecessors in several, different key areas: the sensitivity of the trigger electronics, the flexibility in the definition of the readout window, as well as the maximum speed for the serial event readout. These design improvements, when combined, allow for almost an order of magnitude smaller dead time per event with no measurable degradation of the polarimetric, spectral, imaging or timing capability of the detector, providing a good match for the next generation of X-ray missions.Keywords
All Related Versions
This publication has 6 references indexed in Scilit:
- Design, construction, and test of the Gas Pixel Detectors for the IXPE missionAstroparticle Physics, 2021
- Initial Tests and Characterization of the Readout Electronics for the IXPE MissionIEEE Transactions on Nuclear Science, 2021
- PolarLight: a CubeSat X-ray polarimeter based on the gas pixel detectorExperimental Astronomy, 2019
- Direct reading of charge multipliers with a self-triggering CMOS analog chip with 105k pixels at 50μm pitchNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2006
- An efficient photoelectric X-ray polarimeter for the study of black holes and neutron starsNature, 2001
- Optical imaging chamber for x-ray astronomyOptical Engineering, 1993