Analysis of Thermal Insulation Thickness for a Container House in the Yanqing Zone of the Beijing 2022 Olympic and Paralympic Winter Games
Open Access
- 7 December 2022
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (24) , 16417
Abstract
A large number of temporary housings (THs) were used in the Yanqing zone of the Beijing 2022 Olympic and Paralympic Winter Games. Taking a kind of container house (CH) used in Yanqing zone as a model, the objective of this paper is to analyze the effect of insulation thickness on heating energy consumption and corresponding carbon emission. The effect of service life of THs on economic thickness was also discussed. The simulation model was developed using EnergyPlus and the heating energy consumption with different insulation materials was simulated based on the meteorological parameters of the top of Xiaohaituo Mountain (2177.5 m) and the Olympic/Paralympic Village (950 m) in Yanqing zone. In the simulation process, the thermal insulation performance of the CH was enhanced with reference to the requirements of GB/T 51350-2019 Technical Standard for Nearly Zero Energy Buildings (NZEB) on one hand. Additionally, the insulation performance was evaluated in terms of payback period and carbon emission. On the other hand, the economic thickness of different insulation materials (rock wool (RW), extruded polystyrene (XPS), polyurethane (PU)) and the high performance vacuum insulation panel (HVIP)) for different service lives of CH was studied. Results show that the U-values of the envelope meeting the NZEB standard can decrease approximately 21.4–32.8% of the heating energy consumption, compared with the original envelope. When the service life of CH is extended to 20 years, the carbon emission is reduced by 18.5% and 29.5%. The payback period of HVIP is longest, up to 31.4 a, and the results of economic thickness show that when the service life of the CH ranges from 1 year to 20 years, the economic thickness range of RW is 47–235 mm, XPS is 41–197 mm, PU is 33–149 mm and HVIP is 4–18 mm at the altitude of 2177.5 m. At the altitude of 950 m, the economic thickness range of RW is 28–158 mm, XPS is 26–131 mm, PU is 25–118 mm, and HVIP is 2–12 mm. From an economic point of view, the service life of a CH has a significant impact on the choice of insulation thickness.Keywords
Funding Information
- Ministry of Science and Technology under project (2021YFF0306305)
- Beijing Municipal Science & Technology Commission under project (Z201100005820007)
This publication has 56 references indexed in Scilit:
- The impact of changes in thermal conductivity of polystyrene insulation material under different operating temperatures on the heat transfer through the building envelopeApplied Thermal Engineering, 2016
- Life-cycle assessment of post-disaster temporary housingBuilding Research & Information, 2016
- Optimum insulation thickness determination using the environmental and life cycle cost analyses based entransy approachSustainable Energy Technologies and Assessments, 2015
- Thermal performance analysis of an emergency shelter using dynamic building simulationEnergy and Buildings, 2015
- Comparative environmental life cycle assessment of thermal insulation materials of buildingsEnergy and Buildings, 2014
- Effects of different insulation materials on primary energy and CO2 emission of a multi-storey residential buildingEnergy and Buildings, 2014
- A comparison of residents’ satisfaction with temporary housing: a case study of two temporary housing types in southern TaiwanJournal of the Chinese Institute of Engineers, 2014
- Mathematical modelling of embodied energy, greenhouse gases, waste, time–cost parameters of building projects: A reviewBuilding and Environment, 2013
- A Study on the Improving Direction of Container Housing through Field Survey - Based on the Analysis of 12 cases in the Urban Area -Journal of the Korean Housing Association, 2012
- A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loadsApplied Energy, 2011