Controlled storage conditions prolong stability of biochemical components in whole blood
- 1 January 2005
- journal article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 43 (2) , 210-5
Abstract
Blood specimens from primary care centres are normally transported to central laboratories by mail. This necessitates centrifugation and separation, especially since the potassium ion concentration in whole blood changes during storage at ambient temperature. Thus, because of the growing awareness of and concern for pre-analytical contributions to the uncertainty of measurements, we investigated 27 components and their stability under controlled temperature conditions from 17 to 23°C. We found that storage of whole blood can be prolonged by up to 8–12h for all components examined, including potassium ions, when stored at 20±0.2°C. We conclude that this opens the possibility for establishing a pick-up service, by which whole blood specimens stored at 20–21°C can be collected at the doctor's office, making centrifugation, separation and mailing superfluous. In addition, the turn-around time from sample drawing to reporting the analytical result would be shortened. After investments in thermostatted boxes and logistics, the system could reduce costs for transporting blood samples from general practice centres to central laboratories.Keywords
This publication has 11 references indexed in Scilit:
- Combination of Analytical Quality Specifications Based on Biological Within- and Between-Subject VariationAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2002
- Errors in Laboratory MedicineClinical Chemistry, 2002
- Optimization of preanalytical conditions and analysis of plasma glucose. 1. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitusScandinavian Journal of Clinical and Laboratory Investigation, 2001
- Evaluation of systematic and random factors in measurements of fasting plasma glucose as the basis for analytical quality specifications in the diagnosis of diabetes. 3. Impact of the new WHO and ADA recommendations on diagnosis of diabetes mellitusScandinavian Journal of Clinical and Laboratory Investigation, 2001
- Causes of Unsatisfactory Performance in Proficiency TestingClinical Chemistry, 2000
- Transport and Temperature Effects on Measurement of Serum and Plasma PotassiumJournal of the Royal Society of Medicine, 1999
- Reasons for a Laboratory’s Inability to Report Results for Requested Analytical TestsClinical Chemistry, 1998
- Proposals for Setting Generally Applicable Quality Goals Solely Based on BiologyAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1997
- Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical areaScandinavian Journal of Clinical and Laboratory Investigation, 1988
- The stability of blood, plasma and serum constituents during simulated transportScandinavian Journal of Clinical and Laboratory Investigation, 1981