Three-dimensional imaging of the spine using the EOS system
Authors:
- Zaid Al-AubaidiZAZaid Al-Aubaidi
- David LebelDLDavid Lebel
- Kamaldine OudjhaneKOKamaldine Oudjhane
- Reinhard ZellerRZReinhard Zeller
- 1 September 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics B
- Vol. 22 (5) , 409-412
Abstract
The aim of this study was to evaluate the precision of three-dimensional geometry compared with computed tomography (CT) images. This retrospective study included patients who had undergone both imaging of the spine using the EOS imaging system and CT scanning of the spine. The apical vertebral orientation was also measured using the EOS imaging system and by CT. Other measures such as the Cobb angle and apical vertebral rotation and translation were used as the control variables to evaluate the potential discrepancy between the standing position in EOS imaging and the supine position in CT scanning. The apical vertebral orientations were 8.7° for the first measurement and 8.4° for the second measurement made by the first author, and 10.3° for the measurement made by the second author. The average of these measurements was 9.3° compared with 6.6° (P=0.65) obtained on CT scanning. The precision of EOS-based measurements of vertebral rotation has never been tested in clinical practice. Although it has limitations, this study suggests that the results obtained using EOS are comparable to those obtained on CT.Keywords
This publication has 16 references indexed in Scilit:
- Comparison of 3-Dimensional Spinal Reconstruction AccuracySpine, 2012
- Angle Measurement Reproducibility Using EOSThree-Dimensional Reconstructions in Adolescent Idiopathic Scoliosis Treated by Posterior InstrumentationSpine, 2011
- Breakthrough in three-dimensional scoliosis diagnosis: significance of horizontal plane view and vertebra vectorsEuropean Spine Journal, 2010
- Diagnostic Imaging of Spinal DeformitiesSpine, 2010
- Low-dose helical computed tomography (CT) in the perioperative workup of adolescent idiopathic scoliosisEuropean Radiology, 2008
- Reproducibility of Measuring the Shape and Three-Dimensional Position of Cervical Vertebrae in Upright Position Using the EOS Stereoradiography SystemSpine, 2007
- Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in childrenPediatric Radiology, 1998
- Morphometric evaluations of personalised 3D reconstructions and geometric models of the human spineMedical & Biological Engineering & Computing, 1997
- A New Technique for the Three-Dimensional Study of the Spine In Vitro and In Vivo by Using a Motion-Analysis SystemJournal of Spinal Disorders, 1997
- Estimation of Vertebral Rotation and the Spinal and Rib Cage Deformity in Scoliosis by Computer TomographySpine, 1981