Fractional flow reserve in clinical practice: from wire-based invasive measurement to image-based computation
- 30 December 2019
- journal article
- review article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 41 (34) , 3271-3279
Abstract
Fractional flow reserve (FFR) and instantaneous wave-free ratio are the present standard diagnostic methods for invasive assessment of the functional significance of epicardial coronary stenosis. Despite the overall trend towards more physiology-guided revascularization, there remains a gap between guideline recommendations and the clinical adoption of functional evaluation of stenosis severity. A number of image-based approaches have been proposed to compute FFR without the use of pressure wire and induced hyperaemia. In order to better understand these emerging technologies, we sought to highlight the principles, diagnostic performance, clinical applications, practical aspects, and current challenges of computational physiology in the catheterization laboratory. Computational FFR has the potential to expand and facilitate the use of physiology for diagnosis, procedural guidance, and evaluation of therapies, with anticipated impact on resource utilization and patient outcomes.Keywords
This publication has 40 references indexed in Scilit:
- Utilizing Post-Intervention Fractional Flow Reserve to Optimize Acute Results and the Relationship to Long-Term OutcomesJACC: Cardiovascular Interventions, 2016
- Impact of Side Branch Modeling on Computation of Endothelial Shear Stress in Coronary Artery DiseaseJACC, 2015
- Fractional Flow Reserve and Coronary Bifurcation AnatomyJACC: Cardiovascular Interventions, 2015
- Fractional Flow Reserve Calculation From 3-Dimensional Quantitative Coronary Angiography and TIMI Frame CountJACC: Cardiovascular Interventions, 2014
- Fractional Flow Reserve–Guided RevascularizationJACC: Cardiovascular Interventions, 2013
- Virtual Fractional Flow Reserve From Coronary Angiography: Modeling the Significance of Coronary LesionsJACC: Cardiovascular Interventions, 2013
- Comparison of intravenous adenosine and intravenous regadenoson for the measurement of pressure-derived coronary fractional flow reserveEuroIntervention, 2013
- Coronary Pressure Measurement After Stenting Predicts Adverse Events at Follow-UpCirculation, 2002
- Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography.Circulation, 1994
- Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty.Circulation, 1993