Abstract
Background: To compare mortality after treatment of superficial femoral-popliteal artery disease with paclitaxel and nonpaclitaxel devices using a multicenter vascular registry. Methods: Patients (N=8376) undergoing endovascular treatment of superficial femoral-popliteal artery disease in the Society for Vascular Surgery Vascular Quality Initiative were studied from October 2016 to December 2017. One-year mortality was compared between 3 groups; plain balloon angioplasty (N=2104) versus paclitaxel-coated balloon angioplasty (N=3543), bare-metal stenting (N= 2045) versus paclitaxel-eluting stents (N=684), and combined paclitaxel versus nonpaclitaxel devices. Mortality rates with hazard ratios (HR) and 95% CI were compared in unadjusted and propensity-matched cohorts and illustrated by Kaplan-Meier analysis with subgroup analysis for intermittent claudication, chronic limb-threatening ischemia, and secondary interventions. Results: In propensity-matched analyses, mortality was similar after plain balloon angioplasty (12.6%) and paclitaxel-coated balloon angioplasty (9.6%; HR=0.84 [95% CI, 0.66–1.06], P =0.14). In propensity-matched groups, mortality was similar after bare-metal stenting (9.8%) and paclitaxel-eluting stenting (8.8%; HR=0.93 [95% CI, 0.62–1.41], P =0.75). In the combined, matched analysis mortality was significantly lower in the paclitaxel device group (8.5%) compared with the nonpaclitaxel device group (11.5%; HR=0.82 [95% CI, 0.68–0.98], P =0.03). Secondary interventions were similar after nonpaclitaxel (N=1113/4149, 26.8%) and paclitaxel device use (N=1113/4227, 26.3%). For intermittent claudication, mortality was lower after paclitaxel device use (1.6%) compared with nonpaclitaxel devices (4.4%; adjusted HR=0.59 [95% CI, 0.39–0.89], P =0.01). For chronic limb-threatening ischemia, the mortality difference was not significant; paclitaxel (12.8%) versus nonpaclitaxel devices (15.5%; adjusted HR=0.85 [95% CI, 0.72–1.00], P =0.05). Conclusions: At 1 year, mortality was similar if not lower after treatment of femoral-popliteal occlusive disease with paclitaxel versus nonpaclitaxel devices. This work highlights the potential use of the Society for Vascular Surgery Vascular Quality Initiative for surveillance of the safety of new peripheral arterial devices.Keywords
This publication has 32 references indexed in Scilit:
- Bridging Unmet Medical Device Ecosystem Needs With Strategically Coordinated Registries NetworksJAMA, 2015
- Trial of a Paclitaxel-Coated Balloon for Femoropopliteal Artery DiseaseNew England Journal of Medicine, 2015
- Drug-Coated Balloon Versus Standard Percutaneous Transluminal Angioplasty for the Treatment of Superficial Femoral and Popliteal Peripheral Artery DiseaseCirculation, 2015
- The Data Extraction and Longitudinal Trend Analysis Network Study of Distributed Automated Postmarket Cardiovascular Device Safety SurveillanceCirculation: Cardiovascular Quality and Outcomes, 2015
- Bayesian network meta-analysis of nitinol stents, covered stents, drug-eluting stents, and drug-coated balloons in the femoropopliteal arteryJournal of Vascular Surgery, 2014
- The LEVANT I (Lutonix Paclitaxel-Coated Balloon for the Prevention of Femoropopliteal Restenosis) Trial for Femoropopliteal RevascularizationJACC: Cardiovascular Interventions, 2014
- Paclitaxel-coated balloon or primary bare nitinol stent for revascularization of femoropopliteal artery: A meta-analysis of randomized trials versus uncoated balloon and an adjusted indirect comparisonInternational Journal of Cardiology, 2013
- Sustained Safety and Effectiveness of Paclitaxel-Eluting Stents for Femoropopliteal LesionsJACC, 2013
- Paclitaxel-Coated Versus Uncoated Balloon Angioplasty Reduces Target Lesion Revascularization in Patients With Femoropopliteal Arterial DiseaseCirculation: Cardiovascular Interventions, 2012
- Automated Surveillance to Detect Postprocedure Safety Signals of Approved Cardiovascular DevicesJAMA, 2010