Diagnostic performance of heavily T2-weighted techniques in obstructive hydrocephalus: comparison study of two different 3D heavily T2-weighted and conventional T2-weighted sequences
Authors:
- 7 January 2015
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 33 (2) , 94-101
Abstract
To evaluate efficacy of three-dimensional (3D) heavily T2-weighted (W) MRI sequences in assessment of cerebrospinal fluid (CSF) pathways and to compare two different types of 3D heavily T2W MRI sequences (CISS and SPACE) with two-dimensional (2D) T2W turbo spin echo (TSE) sequences for hydrocephalus with intraventricular obstruction. Sixty-two patients who were diagnosed with intraventricular obstructive hydrocephalus, according to clinical and radiological findings, were included in this retrospective study. 2D-TSE-T2, 3D-CISS, and 3D-SPACE, which are part of the protocol, were analyzed quantitatively by measuring ventricle-to-parenchyma contrast-to-noise ratio (CNR), and qualitatively by evaluating the capabilities of visualization of the obstructive pathology, overall image quality, severity of artifacts, and delineation of the CSF pathways. One-way ANOVA and Friedman’s test were used for statistical analysis. CNR between CSF and brain parenchyma was significantly higher using 3D-SPACE sequences compared with 3D-CISS and 2D-TSE-T2 sequences. The qualitative findings showed that 3D heavily T2W sequences were superior to 2D-TSE-T2 sequences. 3D-SPACE sequences showed fewer artifacts than 3D-CISS or 2D-TSE-T2 sequences. 3D heavily T2W sequences are necessary tools for assessment of CSF pathways in patients with intraventricular obstructive hydrocephalus. 3D-SPACE sequences allowed heavy T2W, which is necessary for CSF flow imaging and provided significantly fewer image artifacts and improved CNR in comparison with 3D-CISS sequences.Keywords
This publication has 17 references indexed in Scilit:
- Evaluation of hydrocephalus and other cerebrospinal fluid disorders with MRI: An updateInsights into Imaging, 2014
- Depicting the semicircular canals with inner‐ear MRI: A comparison of the SPACE and TrueFISP sequencesJournal of Magnetic Resonance Imaging, 2012
- Evaluation of Aqueductal Stenosis by 3D Sampling Perfection with Application-Optimized Contrasts Using Different Flip Angle Evolutions Sequence: Preliminary Results with 3T MR ImagingAmerican Journal of Neuroradiology, 2011
- A consensus on the classification of hydrocephalus: its utility in the assessment of abnormalities of cerebrospinal fluid dynamicsChild's Nervous System, 2011
- Radiologic evaluation of pediatric hydrocephalusChild's Nervous System, 2011
- Phase-contrast MRI and 3D-CISS versus contrast-enhanced MR cisternography on the evaluation of the aqueductal stenosisNeuroradiology, 2009
- N/2 Ghosting Artifacts: Elimination at 3.0-T MR Cholangiography with SPACE Pulse SequenceRadiology, 2008
- Magnetic resonance cisternography for preoperative evaluation of arachnoid cystsNeuroradiology, 2007
- Liliequist Membrane: Three-dimensional Constructive Interference in Steady State MR ImagingRadiology, 2003
- Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the BrainRadiology, 2000