The Use of AFM and Surface Energy Measurements to Investigate Drug-Canister Material Interactions in a Model Pressurized Metered Dose Inhaler Formulation
Open Access
- 1 April 2006
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 40 (4) , 227-236
Abstract
The aim of the project was to investigate the interactions between micronized salbutamol sulphate, budesonide, and formoterol fumarate dihydrate and different canister surfaces materials (Aluminium, anodized aluminium, perfluoroalkoxy, fluorinated ethylene propylene—polyether sulphone, and polytetrafluoroethylene) used in pressurized metered dose inhalers (pMDIs). The surface component approach for polar and apolar interfacial interactions was used to predict the adhesion behavior of micronized drugs with the inner surfaces of pMDI canisters. This was achieved using a combination of in situ colloid probe atomic force microscopy (AFM) measurements and theoretical treatment of the surface free energy measurements, via a contact angle–based technique of the interacting surfaces. All three drugs exhibited similar dispersive surface energy free values. A greater variation was, however, found in the polar component of the surface free energy measurements. These results were also reflected in the dispersive and polar components of the canister materials. Moreover, the linear relationship between the work of adhesion and AFM measured adhesion was shown to be correlated on the polar contributions of the surface free energies of the interacting materials. AFM measurements indicated that salbutamol sulphate was found to have the strongest adhesive forces with respect to the canister surface materials while budesonide and formoterol fumarate dihydrate appeared to have similar adhesive characteristics. The present study suggests that investigations into the design and characterization of pMDI formulations would benefit from considerations of the polar contribution of the surface free energy and relative work of adhesion of the drug and various components of a pMDI system.Keywords
This publication has 33 references indexed in Scilit:
- Compatibility Evaluation of Metered-Dose Inhaler Valve Elastomers with Tetrafluoroethane (P134a), a Non-CFC PropellantDrug Development and Industrial Pharmacy, 1998
- The extent of errors associated with contact angles 3. The influence of surface roughness effects on angles measured using a Wilhelmy plate technique for powdersColloids and Surfaces A: Physicochemical and Engineering Aspects, 1995
- Contact angle, wetting, and adhesion: a critical reviewJournal of Adhesion Science and Technology, 1992
- Direct measurement of colloidal forces using an atomic force microscopeNature, 1991
- Interfacial Lifshitz-van der Waals and polar interactions in macroscopic systemsChemical Reviews, 1988
- Atomic Force MicroscopePhysical Review Letters, 1986
- Effect of contact deformations on the adhesion of particlesJournal of Colloid and Interface Science, 1975
- Surface energy and the contact of elastic solidsProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1971
- adsIndustrial & Engineering Chemistry, 1963
- Ueber die Berührung fester elastischer Körper.Journal für die reine und angewandte Mathematik (Crelles Journal), 1882