Distinguishing Nanoparticle Aggregation from Viscosity Changes in MPS/MSB Detection of Biomarkers
Open Access
Abstract
Magnetic particle spectroscopy (MPS) in the Brownian relaxation regime, also termed magnetic spectroscopy of Brownian motion (MSB), can detect and quantitate very low, sub-nanomolar concentrations of molecular biomarkers. MPS/MSB uses the harmonics of the magnetization induced by a small, low-frequency oscillating magnetic field to provide quantitative information about the magnetic nanoparticles’ (mNPs’) microenvironment. A key application uses antibody-coated mNPs to produce biomarker-mediated aggregation that can be detected using MPS/MSB. However, relaxation changes can also be caused by viscosity changes. To address this challenge, we propose a metric that can distinguish between aggregation and viscosity. Viscosity changes scale the MPS/MSB harmonic ratios with a constant multiplier across all applied field frequencies. The change in viscosity is exactly equal to the multiplier with generality, avoiding the need to understand the signal explicitly. This simple scaling relationship is violated when particles aggregate. Instead, a separate multiplier must be used for each frequency. The standard deviation of the multipliers over frequency defines a metric isolating viscosity (zero standard deviation) from aggregation (non-zero standard deviation). It increases monotonically with biomarker concentration. We modeled aggregation and simulated the MPS/MSB signal changes resulting from aggregation and viscosity changes. MPS/MSB signal changes were also measured experimentally using 100 nm iron-oxide mNPs in solutions with different viscosities (modulated by glycerol concentration) and with different levels of aggregation (modulated by concanavalin A linker concentrations). Experimental and simulation results confirmed that viscosity changes produced small changes in the standard deviation and aggregation produced larger values of standard deviation. This work overcomes a key barrier to using MPS/MSB to detect biomarkers in vivo with variable tissue viscosity.Keywords
Funding Information
- NIH/NIBIB (1R21EB021456)
This publication has 48 references indexed in Scilit:
- Simultaneous quantification of multiple magnetic nanoparticlesNanotechnology, 2010
- Viscous effects on nanoparticle magnetization harmonicsJournal of Magnetism and Magnetic Materials, 2010
- Altered expression of apoptotic factors and synaptic markers in postmortem brain from bipolar disorder patientsNeurobiology of Disease, 2010
- Nanoparticle temperature estimation in combined ac and dc magnetic fieldsPhysics in Medicine & Biology, 2009
- H-Type Dimer Formation of Fluorophores: A Mechanism for Activatable, in Vivo Optical Molecular ImagingACS Chemical Biology, 2009
- Biomolecule induced nanoparticle aggregation: Effect of particle size on interparticle couplingJournal of Colloid and Interface Science, 2007
- Tomographic imaging using the nonlinear response of magnetic particlesNature, 2005
- In vivo MRI of brain inflammation in human ischaemic strokeBrain, 2004
- A New Class of Contrast Agents for MRI Based on Proton Chemical Exchange Dependent Saturation Transfer (CEST)Journal of Magnetic Resonance, 2000
- A Pad approximant to the inverse Langevin functionRheologica Acta, 1991