Time Over Threshold as a measure of energy response of plastic scintillators used in the J-PET detector
Author:
Open Access
- 1 February 2019
- journal article
- research article
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 199, 05014
Abstract
The Jagiellonian Positron Emission Tomograph (J-PET) is a multipurpose detector being developed to provide an economical alternative of commercially available PETs as well as to perform the tests on the discrete symmetries and entanglement. It is composed of 192 plastic scintillators axially arranged in three cylindrical layers. In the framework of J-PET detector, Time-Over-Threshold (TOT) approach is adopted for the signal readouts in order to utilize the excellent time resolution of the plastic scintillators. In this paper, we present a method elaborated for establishing a relation between TOT and energy loss.Keywords
This publication has 24 references indexed in Scilit:
- Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomographPhysics in Medicine & Biology, 2016
- Compressive sensing of signals generated in plastic scintillators in a novel J-PET instrumentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- A novel method for the line-of-response and time-of-flight reconstruction in TOF-PET detectors based on a library of synchronized model signalsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Test of a single module of the J-PET scanner based on plastic scintillatorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission TomographyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Design of a Real-Time FPGA-Based Data Acquisition Architecture for the LabPET II: An APD-Based Scanner Dedicated to Small Animal PET ImagingIEEE Transactions on Nuclear Science, 2013
- TOFPET ASIC for PET applicationsJournal of Instrumentation, 2013
- A new pulse width signal processing with delay-line and non-linear circuit (for ToT)Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- A multi-threshold sampling method for TOF-PET signal processingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009
- A time-over-threshold machine: the readout integrated circuit for the BABAR Silicon Vertex TrackerIEEE Transactions on Nuclear Science, 1997