Effects of atmospheric parameters on radon measurements using alpha-track detectors
Authors:
- 1 February 2014
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 85 (2) , 022101
Abstract
The calibration factors of alpha-track radon detectors (ATDs) are essential for accurate determination of indoor radon concentrations. In this paper, the effects of atmospheric parameters on the calibration factors were theoretically studied and partially testified. Based on the atmospheric thermodynamics theory and detection characteristics of the allyl diglycol carbonate (CR-39), the calibration factors for 5 types of ATDs were calculated through Monte Carlo simulations under different atmospheric conditions. Simulation results showed that the calibration factor increased by up to 31% for the ATDs with a decrease of air pressure by 35.5 kPa (equivalent to an altitude increase of 3500 m), and it also increased by up to 12% with a temperature increase from 5 °C to 35 °C, but it was hardly affected by the relative humidity unless the water-vapor condensation occurs inside the detectors. Furthermore, it was also found that the effects on calibration factors also depended on the dimensions of ATDs. It indicated that variations of the calibration factor with air pressure and temperature should be considered for an accurate radon measurement with a large dimensional ATD, and water-vapor condensation inside the detector should be avoided in field measurements.Keywords
Funding Information
- NNSFC (11075040)
This publication has 13 references indexed in Scilit:
- Radon–Thoron Discriminative Measurements in Gansu Province, China, and Their Implication for Dose EstimatesJournal of Toxicology and Environmental Health, Part A, 2006
- Up-to-date radon-thoron discriminative detector for a large scale surveyReview of Scientific Instruments, 2005
- A simple passive monitor for integrating measurements of indoor thoron concentrationsReview of Scientific Instruments, 2002
- Etched track radiometers in radon measurements: a reviewRadiation Measurements, 1999
- Improved Magnus Form Approximation of Saturation Vapor PressureJournal of Applied Meteorology and Climatology, 1996
- Passive integrating 222Rn and 220Rn cup monitors with CR-39 detectorsEnvironment International, 1996
- Atmospheric Pressure Effects on the Calibration Constant of Alpha-track Radon DetectorsHealth Physics, 1994
- Calculating the Calibration Coefficient For Radon Measurements With the Bare LR 115-II Track DetectorHealth Physics, 1992
- The Influence of Exhalation, Ventilation and Deposition Processes Upon the Concentration of Radon (222Rn), Thoron (220Rn) and Their Decay Products in Room AirHealth Physics, 1978
- Activity and Potential Alpha-energy of 222Radon and 220Radon-daughters in Different Air AtmospheresHealth Physics, 1972