Atrial fibrillation and stroke risk factors in patients with cardiac implantable electronic devices
Open Access
- 27 October 2021
- journal article
- research article
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 28 (3) , 28-36
Abstract
Purpose. Determination the proportion and burden of new-onset atrial fibrillation (AF) in patients with cardiac implantable electronic devices (CIED) and without prior AF and assessing the incidence of risk factors for stroke in patients with AF.Methods. The medical history of 111 patients with CIED with remote monitoring function were analyzed. AF diagnosed by the device was interpreted by an arrhythmologist and cases of significant AF were selected. The group of patients with and without AF was compared for several factors. To clarify the influence of risk factors on the duration of AF, all AF cases were divided into 3 categories depending on the AF burden per day. The first group included patients with an AF burden per day of 0.1% or less (n=10, (45.5%)), the second - from 0.3% to 12.2% (n=7, (31.8%)), and the third group - with 100% (n=5, (22.7%)). Patients with a burden of 0.2%, 12.3-99.9% were absent.Results. Newly diagnosed AF was registered in 19.8% of cases. The risk of stroke among these patients was high - 2 [1; 3] points on the CHA2 DS2 -VASc for men, and 3 [2,75; 3,75] points for women. Hypertension of 2 and 3 degrees was recorded in all patients in the group with an AF burden of 100% per day. That significantly differed from the other 2 groups (p=0.043). In the group with an AF burden of 100%, the levels of NT-proBNP, D-dimer, and creatinine were significantly higher than in the other groups (p=0.037, p=0.031 and p=0.036, respectively). When analyzing the dependence of creatinine level on the presence of AF, the area under the ROC-curve was 0.653 with 95% confidence interval 0.528-0.779 (p=0.017). The proportion of right ventricular pacing in patients with ICD was higher in the group of patients with AF.Conclusion. AF occurs in 1/5 of patients with CIED. All patients with AF were potential candidates for anticoagulation due to their high risk of stroke. The daily burden of AF is positively correlated with the presence and degree of hypertension, as well as with markers of renal dysfunction, chronic heart failure, and thrombosis. Elevated creatinine levels are a predictor of AF.Keywords
This publication has 24 references indexed in Scilit:
- Remote monitoring versus conventional follow-up for implantable cardiac devices: Rationale and design of the PORTLink (PORTuguese Research on Telemonitoring with CareLink) trialRevista Portuguesa de Cardiologia (English Edition), 2013
- Atrial fibrillation in heart failure: The sword of damocles revisitedWorld Journal of Cardiology, 2013
- The relationship between D-dimer level and the development of atrial fibrillation in patients with systolic heart failureJournal of Thrombosis and Thrombolysis, 2011
- Chronic kidney disease as an independent risk factor for new-onset atrial fibrillation in hypertensive patientsJournal Of Hypertension, 2010
- Close bidirectional relationship between chronic kidney disease and atrial fibrillation: The Niigata preventive medicine studyAmerican Heart Journal, 2009
- Renal Impairment and Outcomes in Heart FailureJACC, 2006
- Home Monitoring: what can we expect in the future?Clinical Research in Cardiology, 2006
- Atrial fibrillation management: a prospective survey in ESC Member CountriesEuropean Heart Journal, 2005
- Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node DysfunctionCirculation, 2003
- The EuroHeart Failure survey programme—a survey on the quality of care among patients with heart failure in Europe Part 1: patient characteristics and diagnosisEuropean Heart Journal, 2003