High-energy tibial plateau fractures: external fixation versus plate fixation
Authors:
- 13 September 2014
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 25 (3) , 411-423
Abstract
Whether external or plating fixation is more appropriate for high-energy tibial plateau fractures is still being disputed, our aim was to test the hypothesis whether external fixation can provide a fair outcome with fewer complications, when compared to the results with previously reported data of plating fixation for high-energy tibial plateau fractures. An Ovid of Medline, Embase, and Cochrane Library search was conducted for the relevant English orthopedic journals, and eligible studies, including twenty-four case series and one comparative study containing 885 patients associated with 892 fractures, were enrolled. The results showed there were a higher proportion of men, open fractures, malunion, knee instability, and posttraumatic arthritis occurred in external fixation group than those in plating group (P = 0.007, P = 0.000, P = 0.024, P = 0.006, P = 0.000, respectively), while valgus deformity happened at a significantly higher rate in plate group (P = 0.014). No significant differences were found between the two groups in terms of age, Schatzker type, follow-up, mean time to union, mean range of knee motion, and rate of reoperation. With regard to the functional and radiological outcome assessment, despite what assessment tools were used, most of these studies presented less than 90 % good/excellent results in their high-energy fracture series. Besides, there was a trend for patients in plating group to have a higher risk than those in external fixation group in terms of heterotopic ossification and local irritation (1.23 vs 0.17 %, 4 vs 1.94 %, accordingly). Although lack of good quality randomized control trials, there are rather enough samples supporting the current available results. Meanwhile, future multicentered, randomized, controlled studies should be implemented to test these outcomes.Keywords
This publication has 39 references indexed in Scilit:
- High energy tibial plateau fractures treated with hybrid external fixationJournal of Orthopaedic Surgery and Research, 2011
- Three-Column Fixation for Complex Tibial Plateau FracturesJournal of Orthopaedic Trauma, 2010
- Combination of Fine Wire Fixation and Limited Internal Fixation for High-Energy Tibial Plateau Fractures: Functional Results at Minimum 5-Year Follow-upJournal of Orthopaedic Trauma, 2009
- Treatment of Bicondylar Tibia Plateau Fractures Using Locked Plating Versus External FixationOrthopedics, 2009
- Treatment Strategies for Complex Fractures of the Tibial Plateau With External Circular Fixation and Limited Internal FixationJournal of Trauma: Injury, Infection & Critical Care, 2007
- Functional outcome of tibial plateau fractures treated with the fine-wire fixatorInjury, 2005
- Minimal Internal Fixation Augmented by Small Wire Transfixion Frames for High-Energy Tibial Plateau FracturesJournal of Orthopaedic Trauma, 2005
- Hybrid External Fixation of Comminuted Tibial Plateau FracturesClinical Orthopaedics and Related Research, 1996
- Bicondylar Tibial Plateau Fractures Treated with a Hybrid Ring External Fixator: A Preliminary StudyJournal of Orthopaedic Trauma, 1994
- Incorporating variations in the quality of individual randomized trials into meta-analysisJournal of Clinical Epidemiology, 1992