Comparative Analysis of Strength and Modal Characteristics of a Full Tubular Pump and an Axial Flow Pump Impellers Based on Fluid-Structure Interaction
Open Access
Abstract
Fluid-structure interaction (FSI) was used to determine the structural mechanical characteristics of full tubular and axial-flow pumps. The results showed that as the flow rate increases, the total deformation and equivalent stress are significantly reduced. The max total deformation (MTD) and the max equivalent stress (MES) of the full tubular pump impeller occur on the outer edge of the blade. There are two stress concentrations in the full tubular pump impeller, one of which is located in the outlet area of the rim, and the other is located in the outlet area of the hub. However, the MES of the axial-flow pump appears in the center of the blade hub. The performance difference between the full tubular pump and the axial-flow pump is mainly caused by the clearance backflow. The natural frequency of the full tubular pump is lower than that of the axial-flow pump on the basis of the modal results. The MES of the full tubular pump is mainly concentrated at the junction of the blade and the motor rotor, and the max thickness of the rim is 6mm, which can be more prone to cracks and seriously affect the safety and stability of the pump.Keywords
Funding Information
- National Natural Science Foundation of China (51376155)
- Natural Science Foundation of Jiangsu Province of China (BK20190914)
- China Postdoctoral Science Foundation Project (2019M661946)
- Natural Science Foundation of Jiangsu Higher Education Institutions of China (19KJB570002)
- National Science Foundation of Yangzhou of China (YZ2018103)
- Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD)
This publication has 26 references indexed in Scilit:
- Fluid–structure interaction analysis of fluid pressure pulsation and structural vibration features in a vertical axial pumpAdvances in Mechanical Engineering, 2019
- Unsteady Flow and Vibration Analysis of the Horizontal‐Axis Wind Turbine Blade under the Fluid‐Structure InteractionShock and Vibration, 2019
- Hydroelastic analysis of surface-piercing propeller through one-way and two-way coupling approachesProceedings of the Institution of Mechanical Engineers, Part M: Journal of Engineering for the Maritime Environment, 2018
- Dynamic stress of impeller blade of shaft extension tubular pump device based on bidirectional fluid-structure interactionJournal of Mechanical Science and Technology, 2017
- Vibration characteristics of the impeller at multi-conditions in mixed-flow pump under the action of fluid-structure interactionJournal of Vibroengineering, 2016
- Fluid–structure coupling analysis of deformation and stress in impeller of an axial-flow pump with two-way passageAdvances in Mechanical Engineering, 2016
- Hydro turbine failure mechanisms: An overviewEngineering Failure Analysis, 2014
- A Comparison of One‐Way and Two‐Way Coupling Methods for Numerical Analysis of Fluid‐Structure InteractionsJournal of Applied Mathematics, 2011
- Analysis of dynamic stresses in Kaplan turbine bladesEngineering Computations, 2007
- Two-equation eddy-viscosity turbulence models for engineering applicationsAIAA Journal, 1994