Robotic Ultrasound Scanning With Real-Time Image-Based Force Adjustment: Quick Response for Enabling Physical Distancing During the COVID-19 Pandemic
Authors:
Open Access
- 22 March 2021
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 8, 645424
Abstract
During an ultrasound (US) scan, the sonographer is in close contact with the patient, which puts them at risk of COVID-19 transmission. In this paper, we propose a robot-assisted system that automatically scans tissue, increasing sonographer/patient distance and decreasing contact duration between them. This method is developed as a quick response to the COVID-19 pandemic. It considers the preferences of the sonographers in terms of how US scanning is done and can be trained quickly for different applications. Our proposed system automatically scans the tissue using a dexterous robot arm that holds US probe. The system assesses the quality of the acquired US images in real-time. This US image feedback will be used to automatically adjust the US probe contact force based on the quality of the image frame. The quality assessment algorithm is based on three US image features: correlation, compression and noise characteristics. These US image features are input to the SVM classifier, and the robot arm will adjust the US scanning force based on the SVM output. The proposed system enables the sonographer to maintain a distance from the patient because the sonographer does not have to be holding the probe and pressing against the patient's body for any prolonged time. The SVM was trained using bovine and porcine biological tissue, the system was then tested experimentally on plastisol phantom tissue. The result of the experiments shows us that our proposed quality assessment algorithm successfully maintains US image quality and is fast enough for use in a robotic control loop.Keywords
This publication has 41 references indexed in Scilit:
- Retinal image quality assessment based on image clarity and contentJournal of Biomedical Optics, 2016
- Review of medical image quality assessmentBiomedical Signal Processing and Control, 2016
- Automated quality assessment in three-dimensional breast ultrasound imagesJournal of Medical Imaging, 2016
- Online Stability in Human-Robot Cooperation with Admittance ControlIEEE Transactions on Haptics, 2016
- Optimization of ultrasound image quality via visual servoing2015
- A review of robotic mechanisms for ultrasound examinationsIndustrial Robot: the international journal of robotics research and application, 2014
- Ultrasound confidence maps using random walksMedical Image Analysis, 2012
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Generalized NEQ for assessment of ultrasound image quality2003
- An overview of robot force controlRobotica, 1997