Abstract
Intracytoplasmic sperm injection (ICSI) is an assisted reproductive technology used in infertility treatment, where a single sperm is selected and immobilised using a glass injection pipette and is inserted directly into the cytoplasm of an oocyte under the microscope. Auto-alignment of the injection pipette is a prerequisite for any proposed automated oocyte injection procedure. In this paper, an auto-alignment procedure has been proposed. This technique requires the positioning of the injection and holding pipettes in the three orthogonal axes under microscopy which is complex. The existing proposed methods are system-specific and require appropriate algorithms. In this study, twelve commonly used focusing algorithms were evaluated to verify the optimal one for ICSI application. These algorithms were assessed by measuring focusing accuracy, range, number of false maxima and the width of the curve. The focus level for each pipette is calculated by the algorithm using focus measure functions (FMA). The Fibonacci search algorithm is employed for controlling the z-axis of the motorised stage to obtain the focal plane of the injection and holding pipette. Experimental results verified that the Brenner gradient has demonstrated the highest overall performance for injection pipette focalization, while Energy of gradient has presented a highest overall performance for holding pipette focalization.Keywords
Funding Information
- Medical Research Council
This publication has 33 references indexed in Scilit:
- Autofocus evaluation for brightfield microscopy pathologyJournal of Biomedical Optics, 2012
- Dynamic evaluation of autofocusing for automated microscopic analysis of blood smear and pap smearJournal of Microscopy, 2007
- Autofocusing in computer microscopy: Selecting the optimal focus algorithmMicroscopy Research and Technique, 2004
- Biological Cell Injection Using an Autonomous MicroRobotic SystemThe International Journal of Robotics Research, 2002
- Real-time focus range sensorIEEE Transactions on Pattern Analysis and Machine Intelligence, 1996
- Image quality measures and their performanceIEEE Transactions on Communications, 1995
- Focusing techniquesOptical Engineering, 1993
- Pregnancies after intracytoplasmic injection of single spermatozoon into an oocyteThe Lancet, 1992
- An automated microscope for cytologic research a preliminary evaluation.Journal of Histochemistry & Cytochemistry, 1976
- Sequential Minimax Search for a MaximumProceedings of the American Mathematical Society, 1953