Abstract
Scaphoid fractures are commonly fixed with headless cannulated screws positioned centrally in the scaphoid. Judgement of central placement of the screw may be difficult. We generated a central zone using computer analysis of 3D reconstructions of computed tomography (CT) images. As long as the screw axis is completely contained within this central zone, the screw would be considered as centrally placed. Thirty cases of 3D CT reconstructions of normal scaphoids in a computerised operation planning and simulation system (Vxwork software) were obtained. The central zone was established after some distance shrinkage of the original scaphoid surface reconstruction model using the function “erode” in the software. The shape of the central zone was evaluated, and the width of the central zone in the proximal pole, waist portion and distal pole was measured. We also established the long axis of the scaphoid to see whether it stays in the central zone. All central zones could be divided into distal, waist and proximal portions according to the corresponding irregular shape of the scaphoid. As the geometry of the central zone was so irregular and its width very narrow, it was possible to completely contain the screw axis either in the proximal portion alone, waist alone or distal central zone alone. Establishing the central zone of scaphoid 3D CT images provided a baseline for discussion of central placement of a scaphoid screw. The geometry of the scaphoid central zone determined that the screw could hardly be inserted through entire scaphoid central area during surgery.Keywords
This publication has 20 references indexed in Scilit:
- Incidence of Scaphotrapezial Arthritis Following Volar Percutaneous Fixation of Nondisplaced Scaphoid Waist Fractures Using a Transtrapezial ApproachThe Journal of Hand Surgery, 2011
- The length and position of the long axis of the scaphoid measured by analysis of three-dimensional reconstructions of computed tomography imagesJournal of Hand Surgery (European Volume), 2010
- Optimal Fixation of Acute Scaphoid Fractures: Finite Element AnalysisThe Journal of Hand Surgery, 2010
- Comparison of Percutaneous Dorsal Versus Volar Fixation of Scaphoid Waist Fractures Using a Computer Model in CadaversThe Journal of Hand Surgery, 2009
- Percutaneous fixation of selected scaphoid fractures by dorsal approachInternational Orthopaedics, 2009
- A Computational Approach to the “Optimal” Screw Axis Location and Orientation in the Scaphoid BoneThe Journal of Hand Surgery, 2009
- Technique for Percutaneous Fixation of Displaced and Nondisplaced Acute Scaphoid Fractures and Select NonunionsThe Journal of Hand Surgery, 2008
- Retrograde (Volar) Scaphoid Screw Insertion—A Quantitative Computed Tomographic AnalysisThe Journal of Hand Surgery, 2005
- DEGENERATIVE CHANGES AT THE SCAPHOTRAPEZIAL JOINT FOLLOWING HERBERT SCREW INSERTION: A RADIOGRAPHIC STUDY COMPARING PATIENTS WITH SCAPHOID FRACTURE AND PRIMARY HAND ARTHRITISJournal of Hand Surgery (European Volume), 2000