Abstract
A novel two-dimensional heterodyne detection technique is demonstrated for real-time, cross-sectional imaging using optical coherence domain reflectometry without lateral scanning. The present technique, which is based on a frequency synchronous detection scheme, enables parallel heterodyne detection with an imager such as a charge coupled device camera. Full-field, micrometer-scale, depth-resolved images acquired at a rate of 10 frame/s are presented.Keywords
This publication has 8 references indexed in Scilit:
- Video-rate optical low-coherence reflectometry based on a linear smart detector arrayOptics Letters, 2000
- Real-time reflectivity and topography imagery of depth-resolved microscopic surfacesOptics Letters, 1999
- Optical coherence tomography (OCT): a reviewIEEE Journal of Selected Topics in Quantum Electronics, 1999
- Laser imaging through scattering media by enhancedheterodyne detection and speckle averaging using2D detector arrayElectronics Letters, 1998
- Full-field optical coherence microscopyOptics Letters, 1998
- Optical coherence tomographyJournal of Biomedical Optics, 1996
- Optical Coherence TomographyScience, 1991