Stride Velocity 95 th Centile Detects Decline in Ambulatory Function Over Shorter Intervals than the 6-Minute Walk Test or North Star Ambulatory Assessment in Duchenne Muscular Dystrophy
Authors:
Open Access
- 16 April 2024
- journal article
- research article
- Published by SAGE Publications in Journal of Neuromuscular Diseases
- Vol. 11 (3) , 701-714
Abstract
Background: Stride Velocity 95 th Centile (SV95C) is the first wearable device-derived clinical outcome assessment (COA) to receive European Medicines Agency (EMA) qualification as a primary endpoint in ambulant patients with Duchenne muscular dystrophy (DMD) aged ≥4 years. Objective: To compare SV95C—in its first-ever clinical trial application as a secondary endpoint—with established motor function COAs used in the trial (Four-Stair Climb [4SC] velocity, North Star Ambulatory Assessment [NSAA], and Six-Minute Walk Distance [6MWD]). Methods: SV95C was a secondary endpoint in a subset ( n = 47) of participants in the SPITFIRE/WN40227 trial of taldefgrobep alfa, which was discontinued due to lack of clinical benefit. Participants in the ≤48-week SV95C sub-study were 6–11 years old and received corticosteroids for ≥6 months pre-treatment. Pearson correlations were used to compare SV95C with the other COAs. Responsiveness and changes over time were respectively assessed via standardized response means (SRMs) based on absolute changes and mixed models for repeated measures. Results: SV95C change at Week 24 was –0.07 m/s, with limited variability (standard deviation: 0.16, n = 27). The SRM for SV95C indicated moderate responsiveness to clinical change at the earliest timepoint (Week 12, n = 46), while those of the other COAs did not indicate moderate responsiveness until Week 36 (6MWD, n = 33) or Week 48 (4SC velocity, n = 20; NSAA total score, n = 20). Baseline correlations between SV95C and other COAs were strong ( r = 0.611–0.695). Correlations between SV95C change from baseline to Week 48 and changes in other COAs were moderate to strong ( r = 0.443–0.678).∥ Conclusions: Overall, SV95C demonstrated sensitivity to ambulatory decline over short intervals, low variability, and correlation with established COAs. Although the negative trial precluded demonstration of SV95C’s sensitivity to drug effect, these findings support the continued use of SV95C in DMD clinical trials.Keywords
This publication has 35 references indexed in Scilit:
- Efficacy and Safety of Vamorolone vs Placebo and Prednisone Among Boys With Duchenne Muscular DystrophyJAMA Neurology, 2022
- Home‐based gait analysis as an exploratory endpoint during a multicenter phase 1 trial in limb girdle muscular dystrophy type R2 and facioscapulohumeral muscular dystrophyMuscle & Nerve, 2021
- OUTCOME MEASURESNeuromuscular Disorders, 2021
- Natural history of Type 2 and 3 spinal muscular atrophy: 2‐year NatHis‐SMA studyAnnals of Clinical and Translational Neurology, 2020
- European regulators’ views on a wearable-derived performance measurement of ambulation for Duchenne muscular dystrophy regulatory trialsNeuromuscular Disorders, 2019
- Moving from significance to real-world meaning: methods for interpreting change in clinical outcome assessment scoresQuality of Life Research, 2017
- The 6‐minute walk test and other clinical endpoints in duchenne muscular dystrophy: Reliability, concurrent validity, and minimal clinically important differences from a multicenter studyMuscle & Nerve, 2013
- Development of a Functional Assessment Scale for Ambulatory Boys with Duchenne Muscular DystrophyPhysiotherapy Research International, 2011
- The 6‐minute walk test in Duchenne/Becker muscular dystrophy: Longitudinal observationsMuscle & Nerve, 2010
- The 6‐minute walk test as a new outcome measure in Duchenne muscular dystrophyMuscle & Nerve, 2009