Monitoring partial discharges on 4-kV motor windings
Authors:
- S.M. TetraultSTS.M. Tetrault
- G.C. StoneGSG.C. Stone
- H.G. SeddingHSH.G. Sedding
- 1 January 1999
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 35 (3) , 682-688
Abstract
Partial discharges are a symptom of most of the stator winding insulation deterioration mechanisms found in motors and generators rated 6 kV or more. Thus, partial discharge testing has been used for over 40 years as a means of determining the maintenance requirements of such high-voltage stators. As the benefits of such testing have become more widely known, there has been an interest to apply partial discharge testing to 4 kV motor and generator windings. This paper discusses the theoretical reasons which may limit testing of 4 kV stators. The results of an extensive series of offline partial discharge tests are presented which indicate that partial discharges indeed do occur. The results of a series of online partial discharge tests conducted on about ten 4 kV motors over the past two years show that partial discharges may only occur for a short time prior to failure with some types of failure mechanisms. Thus, to prevent in-service failures, continuous monitoring is necessary. An inexpensive continuous partial discharge monitor is described. It seems that partial discharge monitoring will only be cost effective for very critical process motors and generators where in-service failures may have large financial consequences.Keywords
This publication has 7 references indexed in Scilit:
- Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled invertersIEEE Electrical Insulation Magazine, 1996
- Existence of partial discharges in low-voltage induction machines supplied by PWM drivesIEEE Transactions on Dielectrics and Electrical Insulation, 1996
- Application of partial discharge testing to motor and generator stator winding maintenanceIEEE Transactions on Industry Applications, 1996
- Partial discharge. XXII. High frequency attenuation in shielded solid dielectric power cable and implications thereof for PD locationIEEE Electrical Insulation Magazine, 1996
- Unusual PD pulse phase distributions in operating rotating machinesIEEE Transactions on Dielectrics and Electrical Insulation, 1995
- Stator insulation monitoring of large high voltage motors and generators using online RF techniques in the petrochemical environment1992
- Detection of Slot Discharges in High-Voltage Stator Windings During OperationTransactions of the American Institute of Electrical Engineers, 1951