Air-Gap Flux Position Estimation of Inaccessible Neutral Induction Machines by Zero-Sequence Voltage
Authors:
- Alfio ConsoliACAlfio Consoli
- Giuseppe ScarcellaGSGiuseppe Scarcella
- Antonio TestaATAntonio Testa
- Thomas A. LipoTLThomas A. Lipo
- 1 January 2002
- journal article
- research article
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 30 (1) , 77-88
Abstract
This paper describes a new and straightforward approach to estimate the air-gap flux position in induction machines. The proposed scheme is based on the injection of a high-frequency oscillating stator voltage instead of a three-phase high-frequency voltage, thus allowing a reduction in audible noises and torque ripple. The main feature of the proposed approach is that a simple air-gap flux tracking algorithm is developed using the amplitude variation of the high-frequency component of the zero-sequence voltage. Moreover, the zero-sequence voltage is sensed at the output of the inverter rather than at motor terminals. The estimated position is not influenced by load and parameter variation and can be performed at any frequency, including low and zero frequency. An experimental prototype has been implemented showing the performance of the proposed approach.Keywords
This publication has 5 references indexed in Scilit:
- A new zero-frequency flux-position detection approach for direct-field-oriented-control drivesIEEE Transactions on Industry Applications, 2000
- Flux Tracking Methods for Direct Field OrientationElectric Machines & Power Systems, 1999
- Low- and zero-speed sensorless control of synchronous reluctance motorsIEEE Transactions on Industry Applications, 1999
- Sensorless field-orientation control of an induction machine by high-frequency signal injectionIEEE Transactions on Industry Applications, 1999
- Transducerless field orientation concepts employing saturation-induced saliencies in induction machinesIEEE Transactions on Industry Applications, 1996