Broadband Phase Correction of FT-ICR Mass Spectra via Simultaneous Excitation and Detection
Authors:
- 24 August 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (19) , 5756-5761
Abstract
In typical Fourier transform ion cyclotron resonance (FT-ICR) mass spectra, temporally dispersed excitation and the delay between excitation and detection result in continuous variation of signal phase with frequency in the detected time-domain ion signal. The complex frequency-domain spectrum of such a signal is a linear combination of absorption- and dispersion-mode spectral components with corresponding asymmetric peaks. For this reason, magnitude-mode spectral display is usually employed to yield a phase-independent uniform and symmetrical peak shape at the expense of spectral resolution. In this work, we implement simultaneous excitation and detection to enable Fourier deconvolution to recover absorption-mode spectra for both low- and high-field FT-ICR instruments. These spectra yield resolving power improvement factors approaching the maximum theoretical limit of 2.0, as well as reduction in frequency assignment errors relative to conventional magnitude-mode spectra. The Fourier deconvolution procedure has the additional benefit of correcting for spectral variation resulting from nonuniform power distribution over the excitation bandwidth and the potential benefit of providing useful diagnostic information for interpretation of experimental performance.Keywords
This publication has 14 references indexed in Scilit:
- Frequency shifts due to the interference of resolved peaks in magnitude-mode Fourier-transform ion cyclotron resonance mass spectraJournal of the American Society for Mass Spectrometry, 2002
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- External accumulation of ions for enhanced electrospray ionization fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 1997
- Cyclotron orbital radius determination in Fourier transform ion cyclotron resonance mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1992
- Discrimination between coprecipitated and adsorbed lead on individual calcite particles using laser microprobe mass analysisAnalytical Chemistry, 1988
- Dispersion versus absorption (DISPA) method for automatic phasing of fourier transform ion cyclotron resonance mass spectraRapid Communications in Mass Spectrometry, 1987
- Space charge effects in Fourier transform mass spectrometry. II. Mass calibrationAnalytical Chemistry, 1984
- Convolution Fourier transform ion cyclotron resonance spectroscopyChemical Physics Letters, 1979
- Selective-phase Ion Cyclotron Resonance SpectroscopyCanadian Journal of Chemistry, 1974
- The Measurement ofby Cyclotron ResonancePhysical Review B, 1951