Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration
- 16 January 2016
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 40 (10) , 2163-2169
Abstract
Purpose To assess, with finite element (FE) calculations, whether immediate weight bearing would be possible after surgical stabilization either with cannulated screws or with a locking plate in a split fracture of the lateral tibial plateau (LTP). Methods A split fracture of the LTP was recreated in a FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. A split fracture of the lateral tibial plateau was reproduced by using geometrical data from patient radiographs. A locking screw plate (LP) and a cannulated screw (CS) systems were modelled to virtually reduce the fracture and 80 kg static body-weight was simulated. Results While the simulated body-weight led to clinically acceptable interfragmentary motion, possible traumatic bone shear stresses were predicted nearby the cannulated screws. With a maximum estimation of about 1.7 MPa maximum bone shear stresses, the Polyax system might ensure more reasonable safety margins. Conclusions Split fractures of the LTP fixed either with locking screw plate or cannulated screws showed no clinically relevant IFM in a FE model. The locking screw plate showed higher mechanical stability than cannulated screw fixation. The locking screw plate might also allow full or at least partial weight bearing under static posture at time zero.Keywords
Funding Information
- Asociación Española de Artroscopia (Becas Fundación Española de Artroscopia 2013)
This publication has 32 references indexed in Scilit:
- Knee Adduction Moment and Medial Contact Force – Facts about Their Correlation during GaitPLOS ONE, 2013
- Computer simulating a clinical trial of a load-bearing implant: An example of an intramedullary prosthesisJournal of the Mechanical Behavior of Biomedical Materials, 2011
- Bone mineral density in the proximal tibia varies as a function of static alignment and knee adduction angular momentum in individuals with medial knee osteoarthritisBone, 2006
- The effects of exercise on human articular cartilageJournal of Anatomy, 2006
- Split Depression Tibial Plateau Fractures: A Biomechanical StudyJournal of Orthopaedic Trauma, 2002
- Biomechanical comparison of fixation of type-I fractures of the lateral tibial plateauThe Journal of Bone and Joint Surgery. British volume, 1999
- Split Fractures of the Lateral Tibial Plateau: Evaluation of Three Fixation MethodsJournal of Orthopaedic Trauma, 1996
- Degenerative Arthritis After Tibial Plateau FracturesJournal of Orthopaedic Trauma, 1995
- Tibial Plateau FracturesClinical Orthopaedics and Related Research, 1993
- The mechanical properties of human tibial trabecular bone as a function of metaphyseal locationJournal of Biomechanics, 1983