Change in Dynamic Hyperinflation After Bronchoscopic Lung Volume Reduction in Patients with Emphysema
Open Access
- 24 July 2020
- journal article
- research article
- Published by Springer Nature in Lung
- Vol. 198 (5) , 795-801
Abstract
Background and Purpose: In patients with severe emphysema, dynamic hyperinflation is superimposed on top of already existing static hyperinflation. Static hyperinflation reduces significantly after bronchoscopic lung volume reduction (BLVR). In this study, we investigated the effect of BLVR compared to standard of care (SoC) on dynamic hyperinflation. Methods: Dynamic hyperinflation was induced by a manually paced tachypnea test (MPT) and was defined by change in inspiratory capacity (IC) measured before and after MPT. Static and dynamic hyperinflation measurements were performed both at baseline and 6 months after BLVR with endobronchial valves or coils (treatment group) or SoC (control group). Results: Eighteen patients underwent BLVR (78% female, 57 (43–67) years, FEV1 25(18–37) %predicted, residual volume 231 (182–376) %predicted). Thirteen patients received SoC (100% female, 59 (44–74) years, FEV1 25 (19–37) %predicted, residual volume 225 (152–279) %predicted. The 6 months median change in dynamic hyperinflation in the treatment group was: + 225 ml (range − 113 to + 803) (p < 0.01) vs 0 ml (− 1067 to + 500) in the control group (p = 0.422). An increase in dynamic hyperinflation was significantly associated with a decrease in residual volume (r = − 0.439, p < 0.01). Conclusion: Bronchoscopic lung volume reduction increases the ability for dynamic hyperinflation in patients with severe emphysema. We propose this is a consequence of improved static hyperinflation.Keywords
This publication has 20 references indexed in Scilit:
- Surgical and endoscopic interventions that reduce lung volume for emphysema: a systemic review and meta-analysisThe Lancet Respiratory Medicine, 2019
- Determining the Role of Dynamic Hyperinflation in Patients with Severe Chronic Obstructive Pulmonary DiseaseRespiration, 2015
- Airflow obstruction and exerciseRespiratory Medicine, 2009
- The Connection Between Chronic Obstructive Pulmonary Disease Symptoms and Hyperinflation and Its Impact on Exercise and FunctionThe American Journal of Medicine, 2006
- Standardisation of the measurement of lung volumesEuropean Respiratory Journal, 2005
- Standardisation of spirometryEuropean Respiratory Journal, 2005
- ATS Statement: Guidelines for the Six-Minute Walk TestAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Lung-Volume Reduction Improves Dyspnea, Dynamic Hyperinflation, and Respiratory Muscle FunctionAmerican Journal of Respiratory and Critical Care Medicine, 1997
- Reference values for residual volume, functional residual capacity and total lung capacity. ATS Workshop on Lung Volume Measurements. Official Statement of The European Respiratory SocietyEuropean Respiratory Journal, 1995
- A Self-complete Measure of Health Status for Chronic Airflow Limitation: The St. George's Respiratory QuestionnaireAmerican Review of Respiratory Disease, 1992