Abstract
Amperometric analysis of indigo carmine at a bare screen-printed electrode placed in an FIA system is reported. This compound is easily detected at a potential of -0.3 V (vs. Ag pseudo-reference electrode) without observing any fouling of the electrode surface, thus allowing the repetitive use of the same electrode in a reproducible manner (coefficients of variation down to 7% for more than 20 consecutive determinations). A linear range of three orders of magnitude and a limit of detection in the sub-micromolar range were attained for this molecule. Based on these studies, indirect amperometric measurements of alkaline phosphatase (ALP) activity in solution were easily carried out using 3-indoxyl phosphate substrate. Its hydrolysis catalyzed by ALP gave rise to indigo product. This product is insoluble in aqueous solutions but it was easily converted into its soluble parent compound, indigo carmine, by addition of fuming sulfuric acid to the reaction media. Using this approach, we achieved a linear range of more than one order of magnitude and a limit of detection of 1 U/l ALP, for an enzymatic reaction time of 60 min.Keywords
This publication has 24 references indexed in Scilit:
- Immunosensors—principles and applications to clinical chemistryClinica Chimica Acta, 2001
- An electrochemical immunosensor for milk progesterone using a continuous flow system11Editors SelectionBiosensors and Bioelectronics, 2001
- Sensitive detection for enzyme-linked immunosorbent assays based on the adsorptive stripping voltammetry of indigo in a flow systemAnalytica Chimica Acta, 2001
- Detection of gentamicin in milk by immunoassay and flow injection analysis with electrochemical measurementAnalytica Chimica Acta, 2001
- Screen-printed amperometric microcell for proline iminopeptidase enzyme activity assayBiosensors and Bioelectronics, 2000
- Competitive enzyme immunosensor developed on a renewable carbon paste electrode supportAnalytica Chimica Acta, 1999
- Application of screen-printed electrodes as transducers in affinity flow-through sensor systemsBiosensors and Bioelectronics, 1998
- An immunosensor based on disposable electrodes for rapid estimation of fatty acid-binding protein, an early marker of myocardial infarctionBiosensors and Bioelectronics, 1997
- Subfemtomolar Determination of Alkaline Phosphatase at a Disposable Screen-Printed Electrode Modified with a Perfluorosulfonated Ionomer FilmAnalytical Chemistry, 1997