Quantitative pharmacokinetic analysis of high-temporal-resolution dynamic contrast-enhanced MRI to differentiate the normal-appearing pituitary gland from pituitary macroadenoma
- 11 March 2020
- journal article
- research article
- Published by Springer Nature in Japanese Journal of Radiology
- Vol. 38 (7) , 649-657
Abstract
Purpose To evaluate the usefulness of high-temporal-resolution dynamic contrast-enhanced (DCE) MRI and quantitative pharmacokinetic analysis to differentiate the normal-appearing pituitary gland from a pituitary macroadenoma. Materials and methods Twenty-seven patients with macroadenomas underwent preoperative DCE-MRI with a temporal resolution of 5 s using compressed sensing to obtain pharmacokinetic parameters. Two independent observers localized the normal-appearing pituitary gland on post-contrast T1-weighted images before and after referring to the corresponding Ktrans maps. Agreements between the localizations and intraoperative findings were evaluated using the kappa statistics. The Mann–Whitney U test was used to compare the pharmacokinetic parameters of the normal-appearing pituitary gland and adenoma. Results For both observers, the agreement between the MRI-based localization and the intraoperative findings increased after referring to the Ktrans maps (observer 1, 0.930–1; observer 2, 0.636–0.855). The normal-appearing pituitary gland had significantly higher Ktrans [/min] (1.50 ± 0.80 vs 0.58 ± 0.49, P < 0.0001), kep [/min] (3.19 ± 1.29 vs 2.15 ± 1.18, P = 0.0049), and ve (0.43 ± 0.15 vs 0.25 ± 0.17, P = 0.0003) than adenoma. Conclusion High-temporal-resolution DCE-MRI and quantitative pharmacokinetic analysis help accurately localize the normal-appearing pituitary gland in patients with macroadenomas. The normal-appearing pituitary gland was characterized by higher Ktrans, kep, and ve than macroadenoma. Condensed abstract Dynamic contrast-enhanced MRI with high-temporal-resolution using compressed sensing was used for quantitative pharmacokinetic analysis of pituitary macroadenomas. An observer study, the use of Ktrans maps improved accuracy in localizing the normal-appearing pituitary gland. As compared to an adenoma, the normal-appearing pituitary gland had significantly higher Ktrans, kep, and ve values.Keywords
This publication has 24 references indexed in Scilit:
- High-Resolution DCE-MRI of the Pituitary Gland Using Radialk-Space Acquisition with Compressed Sensing ReconstructionAmerican Journal of Neuroradiology, 2015
- Correlation of volume transfer coefficient Ktrans with histopathologic grades of gliomasJournal of Magnetic Resonance Imaging, 2012
- Usefulness of the dynamic gadolinium-enhanced magnetic resonance imaging with simultaneous acquisition of coronal and sagittal planes for detection of pituitary microadenomasEuropean Radiology, 2011
- On the scope and interpretation of the Tofts models for DCE‐MRIMagnetic Resonance in Medicine, 2011
- Microvessel Density and Area in Pituitary MicroadenomasEndocrine Pathology, 2009
- PITUITARY HORMONAL LOSS AND RECOVERY AFTER TRANSSPHENOIDAL ADENOMA REMOVALNeurosurgery, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Abdominal MR Imaging with a Volumetric Interpolated Breath-hold ExaminationRadiology, 1999
- Complications of Transsphenoidal Surgery: Results of a National Survey, Review of the Literature, and Personal ExperienceNeurosurgery, 1997
- Pituitary adenomas and normal pituitary tissue: enhancement patterns on gadopentetate-enhanced MR imaging.Radiology, 1990