Inelastic Behavior of Bolted Flange Plate Connections
Authors:
- 1 April 2002
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 128 (4) , 492-500
Abstract
The inelastic behavior and failure modes of eight full-scale bolted flange plate connections are discussed. This series of tests investigated two modes of behavior: hinging girder and hinging flange plate mechanisms. The tests demonstrated that this connection type induces several mechanisms of stable inelastic behavior including panel zone distortion, bolt-slip, flange plate hinging, and girder hinging beyond the flange plate connection. The failure mode for five of the eight specimens was by ductile tearing of the net girder section beyond the end of the bolted flange plate connection. These were also specimens that experienced a significant amount of girder hinging. Clamp plates added to the end of the flange plate connection prevented net section tearing for at least one specimen and fractured the beam flange and web in the girder hinge region. One specimen failed by fracture of the flange plate in the heat-affected zone of the welded joint. Finally, the specimen that induced significant flange plate ...Keywords
This publication has 1 reference indexed in Scilit:
- Static Behavior of Beam-to-Column Moment ConnectionsJournal of the Structural Division, 1981