Validity and interobserver agreement of reagent strips for measurement of glucosuria
Authors:
- 21 December 2010
- journal article
- research article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 71 (3) , 248-252
Abstract
Measurement of glucosuria by means of a visually readable reagent test strip is frequently used in a wide variety of clinical settings. The aim of this study was to evaluate the validity and reliability of this semi-quantitative measurement of glucosuria compared to laboratory measurements of glucose concentrations in urine. Reagent test strips (Combur³Test® Roche) from 375 artificially supplemented samples of urine, covering a wide range of glucose concentrations, were independently read by three different observers. Scores of the strips were categorized as 0, 1+, 2+, 3+ or 4+, in ascending degree of glucosuria. Results of the test-strips were compared to the quantitative measurement of urinary glucose concentration in the laboratory. 21.7% of reagent strips readings were discordant with the laboratory measurements (p < 0.001). Under- or overestimating the degree of glucosuria occurs predominantly in category 1+ and 2+. In category '0' only 5.1% of the readings were incorrect. The interobserver-agreement was very good with 85% overall agreement and multirater Kappa 0.81. Interobserver-scores of the reagent strips never deviated more than one category from each other. The validity as well as the interobserver-agreement for the semi-quantitative measurement of glucosuria using reagent strips is moderate, but sufficient for excluding glucosuria. However it is too imprecise for an accurate quantitative measurement. It might only be valuable in settings where automated readings are not available or suitable.Keywords
This publication has 8 references indexed in Scilit:
- Standards of Medical Care in Diabetes—2010Diabetes Care, 2010
- Glucose Regulation in Preterm Newborn InfantsHormone Research in Paediatrics, 2007
- UrinalysisNursing Standard, 2005
- Impact of blood sampling in very preterm infantsScandinavian Journal of Clinical and Laboratory Investigation, 2000
- Interobserver Variation in Interpreting Chest Radiographs for the Diagnosis of Acute Respiratory Distress SyndromeAmerican Journal of Respiratory and Critical Care Medicine, 2000
- Renal function in sick very low birthweight infants: 4. Glucose excretion.Archives of Disease in Childhood, 1992
- Measuring nominal scale agreement among many raters.Psychological Bulletin, 1971
- Weighted kappa: Nominal scale agreement provision for scaled disagreement or partial credit.Psychological Bulletin, 1968