Clinical Characteristics and Outcomes of Older Cardiac Resynchronization Therapy Recipients Using a Pacemaker versus a Defibrillator
- 14 March 2016
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 27 (6) , 730-734
Abstract
CRT‐P versus CRT‐D Outcomes: Background: Cardiac resynchronization therapy (CRT) is commonly used to manage heart failure, yet published guidelines do not distinguish between recommendations for pacemakers (CRT‐P) and defibrillators (CRT‐D) despite significant differences in size, longevity, and cost between these devices. The purpose of this study is to compare the clinical characteristics and outcomes between elderly recipients of CRT‐P and CRT‐D.Methods and Results: Data from 512 patients (405 CRT‐D, 107 CRT‐P) aged ≥75 years with LV ejection fraction ≤35% and QRS duration >120 milliseconds were retrospectively analyzed for baseline characteristics and followed to the primary outcome of all‐cause mortality. Cox proportional hazards models were used to adjust for possible confounders. Results were further validated through propensity matching cohorts. Compared to CRT‐D recipients, CRT‐P patients were older (83 years vs. 81 years, P < 0.001) and had more comorbid conditions (Charlson index = 5 [3–6] vs. 4 [3–5], P = 0.007). During 40.8 months of follow‐up, there were 280 deaths. Compared to CRT‐D patients, CRT‐P recipients had higher unadjusted mortality (HR 1.54, 95% CI 1.15–2.08, P = 0.004). However, this difference lost significance after adjusting for baseline differences between the groups (HR 1.18, 95% CI 0.78–1.77, P = 0.435).Conclusion: Higher all‐cause mortality in older CRT‐P versus CRT‐D patients is largely explained by baseline clinical and demographic differences between the two groups, which are likely the drivers of device selection in real‐world clinical practice, where the published guidelines remain ambiguous. There is a need for randomized studies to determine optimal CRT device selection.Keywords
This publication has 10 references indexed in Scilit:
- Effect of Cardiac Resynchronization Therapy with Implantable Cardioverter Defibrillator versus Cardiac Resynchronization Therapy with Pacemaker on Mortality in Heart Failure Patients: Results of a High-Volume, Single-Centre ExperienceEuropean Journal of Heart Failure, 2014
- Cardiac resynchronisation therapy: pacemaker versus internal cardioverter-defibrillator in patients with impaired left ventricular functionHeart, 2014
- Epidemiology of Heart FailureCirculation Research, 2013
- Long-Term Reverse Remodeling With Cardiac Resynchronization TherapyJACC, 2010
- Prevalence and risk factors related to infections of cardiac resynchronization therapy devicesEuropean Heart Journal, 2009
- Long‐Term Outcomes of CRT‐PM Versus CRT‐D RecipientsPacing and Clinical Electrophysiology, 2009
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureNew England Journal of Medicine, 2004
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- A new method of classifying prognostic comorbidity in longitudinal studies: Development and validationJournal of Chronic Diseases, 1987
- Arrhythmias in ischemic and nonischemic dilated cardiomyopathy: Prediction of mortality by ambulatory electrocardiographyThe American Journal of Cardiology, 1985