Development of a tunable diode laser sensor for CO concentration analysis at laboratory-scale conditions for in situ combustion tests of heavy crude oils
- 3 August 2018
- journal article
- research article
- Published by Optica Publishing Group in Applied Optics
- Vol. 57 (23) , 6707-6716
Abstract
A tunable diode laser-based sensor is reported to monitor carbon monoxide (CO) concentration under conditions similar to those of laboratory-scale tests used to characterize the behavior of heavy crude oil during in situ combustion (ISC). The sensor uses a DFB diode laser operating over the spectral range of the rotational transition R(11) of the first overtone, wherein simulations of spectral absorption bands for CO, , and showed minimal spectral interference. The absorption spectra were calculated using the HiTran 2008 database at temperatures varying between 150°C and 800°C, pressures from 1 to 5 atm, and the typical concentration of major species in ISC characterization experiments. The measurements of CO concentration were conducted at ambient temperature and pressure in a static glass cell of borosilicate, with a path length of 3.81 cm, to validate the CO sensor architecture under controlled laboratory environments. The calibration curve for CO obtained by quantifying the optical density at the line center of R(11) for a molar-concentration range between 0.7% and 3.4% demonstrated a linear response (coefficient of determination of 0.9986). Experiments at 4 atm and 600 K were carried out in a custom-designed optical chamber with two optical wedged sapphire windows (2°) to avoid the etalon effect. CO-absorption spectra were validated by a comparative study with the HiTran database, while a calibration-free methodology using scanned-wavelength direct absorption was investigated for future characterizing experiments involving ISC. Signal to noise ratios (SNRs) were above 40 in the optical chamber and higher than 14 in the glass cell. The TDL sensor was also successfully validated during real ISC experiments involving Colombian heavy crude oil. The calibration and oxidation experiments showed the potential of TDL-based sensors in the region of 2.3 μm for non-invasive, real-time, and in situ measurements of carbon monoxide generated at similar conditions to those of lab-scale experimental ISC tests.
Keywords
Funding Information
- Departamento Administrativo de Ciencia, Tecnología e Innovación (COLCIENCIAS) (RC 0264-2013)
- Ecopetrol (RC 0264-2013)
This publication has 33 references indexed in Scilit:
- Infrared laser-absorption sensing for combustion gasesProgress in Energy and Combustion Science, 2017
- Scanned-wavelength-modulation-spectroscopy sensor for CO, CO2, CH4 and H2O in a high-pressure engineering-scale transport-reactor coal gasifierFuel, 2015
- High-temperature measurements of methane and acetylene using quantum cascade laser absorption near 8 μmJournal of Quantitative Spectroscopy and Radiative Transfer, 2015
- Sensitive and rapid laser diagnostic for shock tube kinetics studies using cavity-enhanced absorption spectroscopyOptics Express, 2014
- Kinetic Models for Low Temperature Oxidation Subranges based on Reaction Products2013
- Fiber-coupled 2.7 µm laser absorption sensor for CO2in harsh combustion environmentsMeasurement Science and Technology, 2013
- In-Situ Combustion Dynamics Visualized With X-Ray Computed TomographySPE Journal, 2011
- Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environmentsApplied Optics, 2009
- The Challenge of Predicting Field Performance of Air Injection Projects Based on Laboratory and Numerical ModellingJournal of Canadian Petroleum Technology, 2009
- IN SITU COMBUSTION IN ENHANCED OIL RECOVERY (EOR): A REVIEWChemical Engineering Communications, 2007