Comparison of a supplemental wide field of view versus a single field of view with zoom on performance in minimally invasive surgery
- 31 October 2007
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 22 (6) , 1445-1451
Abstract
The limited space and high magnification involved in minimally invasive surgery (MIS) can cause surgeons to lose sight of an instrument while performing tasks such as suturing and knot-tying. A current strategy employed to locate the instrument is zooming out and in with the endoscope, which can be a time-intensive and iterative task. This study investigates the use of a supplemental wide field of view (FOV) via a second endoscope for locating an instrument outside the FOV in a MIS setting. Ten surgically naïve subjects performed a simple aimed movement task with either hand (dominant or nondominant) under two display conditions: (1) conventional single monitor with zoom, and (2) supplemental wide FOV monitor with no zoom. The task emulated the need to locate an instrument outside the surgeon’s FOV and return it to a home position. The supplemental wide FOV produced significantly faster times [F(3,716) = 173.2, p < 0.001)] compared to a single monitor. The task was accomplished most quickly with the dual monitor with the dominant hand, followed by dual monitor with nondominant hand followed by a single monitor with either hand. There were also significantly fewer errors (t = 3.734, df = 9, p = 0.005) with the supplemental wide FOV. None of the subjects were slower with the dual monitor, and all but one had fewer errors. The variance for both task times and errors were also significantly smaller (p < 0.001 and p = 0.008, respectively) with the supplemental wide FOV indicating that subjects performed with increased reliability. The supplemental wide FOV gave the subjects the ability to see their instrument at all times providing a more efficient display than zooming out and in. This enabled faster times and fewer errors while allowing the user to perform the task with more consistency.Keywords
This publication has 19 references indexed in Scilit:
- Comparison of Two-Dimensional and Three-Dimensional Suturing: Is There a Difference in a Robotic Surgery Setting?Journal of Endourology, 2005
- Comparison of Skill Training with Robotic Systems and Traditional Endoscopy: Implications on Training and AdoptionJournal of Surgical Research, 2005
- Surgical robotics: Impact of motion scaling on task performanceJournal of the American College of Surgeons, 2004
- An experimental comparison of 3‐dimensional and 2‐dimensional endoscopic systems in a model 1Arthroscopy, 2004
- Evaluation of Face-Mounted Binocular Video Display for Laparoscopy: Outcomes of Psychometric Skills Testing and Surgeon SatisfactionJournal of Laparoendoscopic & Advanced Surgical Techniques, 2003
- Comparison of laparoscopic skills performance between standard instruments and two surgical robotic systemsSurgical Endoscopy, 2003
- Comparison of conventional and gaze-down imaging in laparoscopic task performanceSurgical Endoscopy, 2003
- Surgeon workload and motion efficiency with robot and human laparoscopic camera controlSurgical Endoscopy, 2002
- A Comparative Experimental Study Evaluating the Performance of Surgical Robots Aesop and EndosistaSurgical Laparoscopy, Endoscopy & Percutaneous Techniques, 2000
- Comparison of Robotic Versus Human Laparoscopic Camera ControlJournal of Urology, 1995