Electronic properties of anodized TiO2 electrodes and the effect on in vitro response
- 21 November 2013
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 102 (4) , 826-839
Abstract
For dental implants, improved osseointegration is obtained by modifying the surface roughness as well as oxide morphology and composition. A combination of different effects contributes to enhanced performance, but with surface roughness as the dominant factor. To single out the effect of oxide conductivity on biological response, oxide films with similar thickness and surface roughness but different electronic properties were formed using galvanostatic anodization. Three different current densities were used, 2.4, 4.8, and 11.9 mA cm−2, which resulted in growth rates ranging from 0.2 to 2.5 V s−1. The electronic properties were evaluated using cyclic voltammetry and impedance spectroscopy, while the biological response was studied by cell activity and apatite formation. The number of charge carrier in the oxide film close to the oxide/solution interface decreased from 5.8 × 10−19 to 3.2 × 10−19 cm−2 with increasing growth rate, that is, the conductivity decreased correspondingly. Cell response of the different surfaces was tested in vitro using human osteoblast‐like cells (MG‐63). The results clearly show decreased osteoblast proliferation and adhesion but higher mineralization activity for the oxide with lower conductivity at the oxide/solution interface. The apatite‐forming ability was examined by immersion in simulated body fluid. At short times the apatite coverage was ∼26% for the anodized surfaces, significantly larger than for the reference with only 3% coverage. After 1 week of immersion the apatite coverage ranged from 73 to 56% and a slight differentiation between the anodized surfaces was obtained with less apatite formation on the surface with lower conductivity, in line with the cell culture results. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 102B: 826–839, 2014.Keywords
This publication has 55 references indexed in Scilit:
- Determination of effective capacitance and film thickness from constant-phase-element parametersElectrochimica Acta, 2010
- Photoelectrochemical behaviour of anatase nanoporous films: effect of the nanoparticle organizationNanoscale, 2010
- Titanium surfaces structured with regular geometry—material investigations and cell morphologySurface and Interface Analysis, 2010
- Effect of Current Density on the Internal Stress Evolution during Galvanostatic Ti Thin Film AnodizingJournal of the Electrochemical Society, 2010
- Integrin α2β1 plays a critical role in osteoblast response to micron-scale surface structure and surface energy of titanium substratesProceedings of the National Academy of Sciences, 2008
- Importance of the band gap energy and flat band potential for application of modified TiO2 photoanodes in water photolysisJournal of Power Sources, 2008
- Requirement for both micron- and submicron scale structure for synergistic responses of osteoblasts to substrate surface energy and topographyBiomaterials, 2007
- The electronic structure of the passive film on tungstenElectrochimica Acta, 2000
- Coloring titanium and related metals by electrochemical oxidationJournal of Chemical Education, 1993
- A Mathematical Model for the Influence of Deep‐Level Electronic States on Photoelectrochemical Impedance Spectroscopy: II . Assessment of Characterization Methods Based on Mott‐Schottky TheoryJournal of the Electrochemical Society, 1992