Bone regeneration with glass ceramic implants and calcium phosphate cements in a rabbit cranial defect model
- 22 September 2010
- journal article
- research article
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 21 (10) , 2853-2859
Abstract
Hydroxyapatite cement (BoneSource®) and brushite calcium phosphate cement (chronOS™ Inject) were tested for fixation of glass ceramic implants (Bioverit®) in experimentally created cranial defects in 24 adult New Zealand White rabbits. Aim of the in vivo study was to assess and compare the biocompatibility and osseointegration of the implanted materials. Macroscopic and histological evaluations were performed 1 month, 3 months, and 6 months postoperatively. All implanted materials were well tolerated by the surrounding tissue. Both bone cements exhibited osteoconductive properties. Differences could be detected regarding to the rates of cement resorption and new bone formation. The brushite cement was resorbed faster than the hydroxyapatite cement. The chronOS™ Inject samples exhibited a higher rate of connective tissue formation and an insufficient osseointegration. BoneSource® was replaced by bone with minimal invasion of connective tissue. New bone formation occurred faster compared to the chronOS™ Inject group. Bioverit® implants fixed with BoneSource® were successfully osseointegrated.Keywords
This publication has 24 references indexed in Scilit:
- Hydroxyapatite Cement in Craniofacial Reconstruction: Experience in 150 PatientsPlastic and Reconstructive Surgery, 2006
- Evaluierung individueller, in der CAD/CAM-Technik gefertigter Bioverit®-Keramik-Implantate zur Wiederherstellung mehrdimensionaler kraniofazialer Defekte am menschlichen SchädelMund-,Kiefer- und Gesichtschirurgie, 2006
- Biocompatibility and resorption of a brushite calcium phosphate cementBiomaterials, 2005
- Assessment of the suitability of a new brushite calcium phosphate cement for cranioplasty – an experimental study in sheepJournal of Cranio-Maxillofacial Surgery, 2005
- The use of hydroxyapatite cements in craniofacial surgeryClinics in Plastic Surgery, 2004
- Hydroxyapatite cement (BoneSourceTM) for repair of critical sized calvarian defects—an experimental studyJournal of Cranio-Maxillofacial Surgery, 2003
- Implantologie in der Kopf-Hals-Chirurgie — gegenwärtiger Stand1992
- Hydroxyapatite Cement: II. Obliteration and Reconstruction of the Cat Frontal SinusJAMA Otolaryngology–Head & Neck Surgery, 1991
- Rasterelektronenmikroskopische Untersuchung des Zellwachstums auf maschinell bearbeitbarer Biovitrokeramik und Glaskohlenstoff in vitro und in vivoLaryngo-Rhino-Otologie, 1985
- A method for the study of undecalcified bones and teeth with attached soft tissues*Journal of Oral Pathology & Medicine, 1982