Multicenter validation of a machine learning phase space electro-mechanical pulse wave analysis to predict elevated left ventricular end diastolic pressure at the point-of-care
Open Access
- 15 November 2022
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (11) , e0277300
Abstract
Phase space is a mechanical systems approach and large-scale data representation of an object in 3-dimensional space. Whether such techniques can be applied to predict left ventricular pressures non-invasively and at the point-of-care is unknown. This study prospectively validated a phase space machine-learned approach based on a novel electro-mechanical pulse wave method of data collection through orthogonal voltage gradient (OVG) and photoplethysmography (PPG) for the prediction of elevated left ventricular end diastolic pressure (LVEDP). Consecutive outpatients across 15 US-based healthcare centers with symptoms suggestive of coronary artery disease were enrolled at the time of elective cardiac catheterization and underwent OVG and PPG data acquisition immediately prior to angiography with signals paired with LVEDP (IDENTIFY; NCT #03864081). The primary objective was to validate a ML algorithm for prediction of elevated LVEDP using a definition of ≥25 mmHg (study cohort) and normal LVEDP ≤ 12 mmHg (control cohort), using AUC as the measure of diagnostic accuracy. Secondary objectives included performance of the ML predictor in a propensity matched cohort (age and gender) and performance for an elevated LVEDP across a spectrum of comparative LVEDP (<12 through 24 at 1 mmHg increments). Features were extracted from the OVG and PPG datasets and were analyzed using machine-learning approaches. The study cohort consisted of 684 subjects stratified into three LVEDP categories, ≤12 mmHg (N = 258), LVEDP 13–24 mmHg (N = 347), and LVEDP ≥25 mmHg (N = 79). Testing of the ML predictor demonstrated an AUC of 0.81 (95% CI 0.76–0.86) for the prediction of an elevated LVEDP with a sensitivity of 82% and specificity of 68%, respectively. Among a propensity matched cohort (N = 79) the ML predictor demonstrated a similar result AUC 0.79 (95% CI: 0.72–0.8). Using a constant definition of elevated LVEDP and varying the lower threshold across LVEDP the ML predictor demonstrated and AUC ranging from 0.79–0.82. The phase space ML analysis provides a robust prediction for an elevated LVEDP at the point-of-care. These data suggest a potential role for an OVG and PPG derived electro-mechanical pulse wave strategy to determine if LVEDP is elevated in patients with symptoms suggestive of cardiac disease.Keywords
Funding Information
- CorVista Health
This publication has 34 references indexed in Scilit:
- STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy StudiesClinical Chemistry, 2015
- Isolation-Based Anomaly DetectionACM Transactions on Knowledge Discovery From Data, 2012
- Extensions of net reclassification improvement calculations to measure usefulness of new biomarkersStatistics in Medicine, 2010
- Characterization of Static and Dynamic Left Ventricular Diastolic Function in Patients With Heart Failure With a Preserved Ejection FractionCirculation: Heart Failure, 2010
- Recommendations for the Standardization and Interpretation of the ElectrocardiogramCirculation, 2007
- Regularization and Variable Selection Via the Elastic NetJournal of the Royal Statistical Society Series B: Statistical Methodology, 2005
- Rapid Measurement of B-Type Natriuretic Peptide in the Emergency Diagnosis of Heart FailureNew England Journal of Medicine, 2002
- Ensemble Methods in Machine Learning2000
- Improved left ventricular diastolic filling in patients with coronary artery disease after percutaneous transluminal coronary angioplasty.Circulation, 1982
- Effects of isometric exercise on the end-diastolic pressure, volumes, and function of the left ventricle in man.Circulation, 1976